Activated sludge
1411188
221026960
2008-06-22T18:53:07Z
DOI bot
6652755
Citation maintenance. Initiated by [[User:Fconaway|Fconaway]]. You can [[WP:DOI|use this bot]] yourself! Please [[User:DOI_bot/bugs|report any bugs]].
'''Activated sludge''' is a process dealing with the treatment of [[sewage]] and [[Wastewater treatment|industrial wastewaters]].<ref name=Beychok>{{cite book | author=Beychok, Milton R. | title=[[Aqueous Wastes from Petroleum and Petrochemical Plants]]| edition=1st Edition | publisher=John Wiley & Sons Ltd | year=1967 | id=[[Library of Congress Control Number|LCCN 67019834]]}}</ref> Atmospheric air or pure [[oxygen]] is bubbled through primary treated sewage (or industrial wastewater) combined with organisms to develop a biological [[flocculation|floc]] which reduces the [[organic matter|organic]] content of the [[sewage]]. The combination of raw sewage (or industrial wastewater) and biological mass is commonly known as Mixed Liquor. In all activated sludge plants, once the sewage (or industrial wastewater) has received sufficient treatment, excess mixed liquor is discharged into settling tanks and the treated [[supernatant]] is run off to undergo further treatment before discharge. Part of the settled material, the [[sludge]], is returned to the head of the [[aeration]] system to re-seed the new sewage (or industrial wastewater) entering the tank. This fraction of the floc is called Return Activated Sludge (R.A.S.). Excess sludge which eventually accumulates beyond what is returned is called Waste Activated Sludge (W.A.S.). W.A.S is removed from the treatment process to keep the ratio of biomass to food supplied (sewage or wastewater) in balance. This is called the F:M ratio. W.A.S is stored away from the main treatment process in storage tanks and is further treated by digestion, either under anaerobic or aerobic conditions prior to disposal.
'''Activated sludge''' is also the name given to the active biological material produced by activated sludge plants and which affects all the purification processes. This material, which in healthy sludge is a brown floc, is largely composed off [[saprotrophic]] [[bacterium|bacteria]] but also has an important [[protozoa]]n flora mainly composed of [[amoeba]]e, [[Spirotrich]]s, [[Peritrich]]s including [[Vorticella|Vorticellids]] and a range of other filter feeding species. Other important constituents include motile and sedentary [[Rotifer]]s. In poorly managed activated sludge, a range of [[mucilage|mucilaginous]] filamentous bacteria can develop including ''Sphaerotilus natans'' which produces a sludge that is difficult to settle and can result in the sludge blanket decanting over the weirs in the settlement tank to severely contaminate the final effluent quality. This material is often described as sewage fungus but true fungal communities are relatively uncommon.
==Purpose==
In a sewage (or industrial wastewater) treatment plant, the activated sludge process can be used for one or several of the following purpose:
* oxidizing carbonaceous matter: [[biological matter]].
* oxidizing nitrogeneous matter: mainly [[ammonium]] and [[nitrogen]] in biological materials.
* removing [[phosphate]].
* driving off entrained gases [[carbon dioxide]], [[ammonia]], nitrogen, etc.
* generating a biological floc that is easy to settle.
* generating a liquor low in dissolved or suspended material.
== History ==
The activated sludge process was discovered in 1913 in the UK by engineers conducting research for the Manchester Corporation Rivers Department at Davyhulme Sewage Works. Experiments on treating sewage in a draw-and-fill reactor (the precursor to today's [[sequencing batch reactor]]) produced a highly treated effluent. Believing that the sludge had been activated (in a similar manner to [[activated carbon]]) the process was named ''activated sludge''. Not until much later was it realized that what had actually occurred was a means to concentrate biological organisms, decoupling the liquid retention time (ideally, low, for a compact treatment system) from the solids retention time (ideally, fairly high, for an effluent low in BOD<sub>5</sub> and ammonia.)
==General principles==
===Definitions===
* Raw water: water entering the system.
* Mixed liquor: the mix of raw water and activated sludge.
* Return activated sludge (R.A.S): activated sludge extracted from the system and mixed with raw water to form the mixed liquor.
* Waste activated sludge (W.A.S.)/Surplus activated sludge (S.A.S.): excess activated sludge that is extracted from the system to be directed to sludge treatment.
* Sludge age: the average time biological that the sludge stays in the system. In simpler words, it can be defined as the average age of bacteria in the system.
[[Image:Activated Sludge 1.png|thumb|right|300 px|A generalized, schematic diagram of an activated sludge process.]]
===Arrangement===
As shown in the diagram to the right, the general arrangement of an activated sludge process for removing carbonaceous pollution includes the following items:
* Aeration tank where air (or oxygen) is injected in the mixed liquor.
* Settling tank (usually referred to as "final clarifier" or "secondary settling tank") to allow the biological flocs to settle, thus separating the biological sludge from the clear treated water.
Treatment of nitrogenous matter or phosphate involves additional steps where the mixed liquor is left in anoxic condition (meaning that there is no residual dissolved oxygen).
==Types of plants==
There are a variety of types of activated sludge plants.<ref name=Beychok/> These include:
===Package plants ===
There are a wide range of other types of plants, often serving small communities or industrial plants that may use hybrid treatment processes often involving the use of aerobic sludge to treat the incoming sewage. In such plants the primary settlement stage of treatment may be omitted. In these plants, a biotic floc is created which provides the required substrate.
Package plants are commonly variants of extended aeration, to promote the 'fit & forget' approach required for small communities without dedicated operational staff. There are various standards to assist with their design.<ref>[http://www.britishwater.co.uk/Document/Download.aspx?uid=3d63842c-eb86-48b1-be17-12eebf7487a5 Code of Practice, ''Flows and Loads-2'', British Water]</ref><ref>[http://products.ihs.com/cis/Doc.aspx?AuthCode=&DocNum=252510 Review of UK and international standards]</ref><ref>[http://www.standardsdirect.org/standards/standards4/StandardsCatalogue24_view_5158.html British Standard BS 6297:1983]</ref>
===Oxidation ditch===
[[Image:Pelican Bay.jpg|right|thumb|200px|left|Oxidation Ditch at Pelican Bay State Prison in Northern California, Courtesy of Siemens Water Technologies Corporation]]
In some areas, where more land is available, sewage is treated in large round or oval ditches with one or more horizontal aerators typically called brush or disc aerators which drive the mixed liquor around the ditch and provide aeration.<ref name=Beychok/> These are oxidation ditches, often referred to by manufacturer's trade names such as Pasveer, Orbal, or Carrousel. They have the advantage that they are relatively easy to maintain and are resilient to shock loads that often occur in smaller communities (i.e at breakfast time and in the evening).
Oxidation ditches are installed commonly as 'fit & forget' technology, with typical design parameters of a [[hydraulic retention time]] of 24 - 48 hours, and a sludge age of 12 - 20 days. This compares with nitrifying activated sludge plants having a retention time of 8 hours, and a sludge age of 8 - 12 days.
===Deep Shaft===
Where land is in short supply sewage may be treated by injection of oxygen into a pressured return sludge stream which is injected into the base of a deep columnar tank buried in the ground. Such shafts may be up to 100 metres deep and are filled with sewage liquor. As the sewage rises the oxygen forced into solution by the pressure at the base of the shaft breaks out as molecular oxygen providing a highly efficient source of oxygen for the activated sludge biota. The rising oxygen and injected return sludge provide the physical mechanism for mixing of the sewage and sludge. Mixed sludge and sewage is decanted at the surface and separated into supernatant and sludge components. The efficiency of deep shaft treatment can be high.
Surface aerators are commonly quoted as having an aeration efficiency of 0.5 - 1.5 kg O<sub>2</sub>/kWh, diffused aeration as 1.5 - 2.5 kg O<sub>2</sub>/KWh. Deep Shaft claims 5 - 8 kg O<sub>2</sub>/kWh.
However, the costs of construction are high. Deep Shaft has seen greatest uptake in Japan, because of the land area issues. Deep Shaft was developed by [[ICI]], as a spin-off from their [[Pruteen]] process. In the UK it is found at three sites: Tilbury, Anglian water, treating a wastewater with a high industrial contribution;<ref>[http://cat.inist.fr/?aModele=afficheN&cpsidt=8054833 Tilbury construction]</ref> Southport, United Utilities, because of land space issues; and Billingham, ICI, again treating industrial effluent, and built (after the Tilbury shafts) by ICI to help the agent sell more.
DeepShaft is a patented, licensed, process. The licensee has changed several times and, currently (2007), it is Aker Kvaerner Engineering Services.<ref>[http://www.akerkvaerner.com/NR/rdonlyres/3EA1C953-F85D-4B29-80E3-516F0908D86E/12470/DeepShaftProcessJuly2005.pdf Deep Shaft Process Technology]</ref>
===Surface-aerated basins===
[[Image:Surface-Aerated Basin.png|thumb|right|318px|A Typical Surface-Aerated Basing (using motor-driven floating aerators)]]
Most biological oxidation processes for treating industrial wastewaters have in common the use of oxygen (or air) and microbial action. Surface-aerated basins achieve 80 to 90% removal of [[BOD]] with retention times of 1 to 10 days.<ref name=Basin>{{cite journal|author=Beychok, M.R.|year=1971|month=|title=Performance of surface-aerated basins|journal=Chemical Engineering Progress Symposium Series|volume=67|issue=107|pages=322–339|issn=}} [http://md1.csa.com/partners/viewrecord.php?requester=gs&collection=ENV&recid=7112203&q=&uid=788301038&setcookie=yes Available at CSA Illumina website]</ref> The basins may range in depth from 1.5 to 5.0 metres and utilize motor-driven aerators floating on the surface of the wastewater.<ref name=Basin/>
In an aerated basin system, the aerators provide two functions: they transfer air into the basins required by the biological oxidation reactions, and they provide the mixing required for dispersing the air and for contacting the reactants (that is, oxygen, wastewater and microbes). Typically, the floating surface aerators are rated to deliver the amount of air equivalent to 1.8 to 2.7 kg [[Oxygen|O<sub>2</sub>]]/[[kW]]h. However, they do not provide as good mixing as is normally achieved in activated sludge systems and therefore aerated basins do not achieve the same performance level as activated sludge units.<ref name=Basin/>
Biological oxidation processes are sensitive to temperature and, between 0 °C and 40 °C, the rate of biological reactions increase with temperature. Most surface aerated vessels operate at between 4 °C and 32 °C.<ref name=Basin/>
== Aeration methods ==
===Diffused Aeration===
[[Image:DualAir Grid System.jpg|thumb|200px|right|Fine bubble membrane diffusers in an aeration tank]]
Sewage liquor is run into deep tanks with diffuser blocks attached to the floor. These are like the diffuser blocks used in [[tropical fish]] tanks but on a much larger scale. Air is pumped through the blocks and the curtain of bubbles formed both oxygenates the liquor and also provide the necessary stirring action. Where capacity is limited or the sewage is unusually strong or difficult to treat, oxygen may be used instead of air. Typically, the air is generated by some type of blower or compressor.
=== Surface aerators (cones) ===
Vertically mounted tubes of up to 1 metre diameter extending from just above the base of a deep concrete tank to just below the surface of the sewage liquor. A typical shaft might be 10 metres high. At the surface end the tube is formed into a cone with helical vanes attached to the inner surface. When the tube is rotated, the vanes spin liquor up and out of the cones drawing new sewage liquor from the base of the tank. In many works each cone is located in a separate cell that can be isolated from the remaining cells if required for maintenance. Some works may have two cones to a cell and some large works may have 4 cones per cell.
== See also ==
*[[Aerated lagoon]]
*[[Aerobic granular reactor]]
*[[Industrial wastewater treatment]]
*[[List of waste water treatment technologies]]
*[[Rotating biological contactor]]
*[[Sewage treatment]]
*[[Trickling filter]]
== References ==
{{reflist}}
== External links ==
* [http://www.iea.lth.se/sbr/iawq/iawq.pdf Modelling using ASM1]
* [http://www.ce.utexas.edu/prof/speitel/steady/steady.htm Steady-state activated sludge model]
* [http://biomath.rug.ac.be/publications/download Various PhD theses on modelling activated sludge systems]
* [http://www.benchmarkwwtp.org/ Detailed algorithms for ASM1 and Takacs settling tank model]
* [http://www.darenet.nl/nl/page/repository.item/show?saharaIdentifier=tuddare:oai:tudelft.nl:161787 Metabolic activated sludge model]
* [http://www.epa.gov/owm/mtb/apartlag.pdf Aerated, Partial Mix Lagoons] (Wastewater Technology Fact Sheet by the [[U.S. EPA]])
* [http://www.ces.clemson.edu/ees/rich/technotes/index.html Aerated Lagoon Technology] (Linvil G. Rich, Professor Emeritus, Department of Environmental Engineering and Science, [[Clemson University]])
[[Category:Waste treatment technology]]
[[Category:Sewerage]]
[[Category:Environmental engineering]]
[[Category:Chemical engineering]]
[[cs:Aktivovaný kal]]
[[de:Belebtschlamm]]
[[fr:Boue activée]]
[[it:Fanghi attivi]]
[[ja:活性汚泥]]
[[pt:Lodo ativado]]
[[ru:Активный ил]]
[[zh:活性污泥法]]