High-intensity discharge lamp
877167
224404908
2008-07-08T18:28:45Z
Scheinwerfermann
360436
Grammar
{{nofootnotes}}
{{Redirect|Flood light||Floodlight}}
[[Image:Xenon short arc 1.jpg|thumb|right|250px|15 kW xenon short-arc lamp used in [[IMAX]] projectors]]
A '''High-intensity discharge''' (HID) lamp is a type of [[electric light|electrical lamp]] which produces light by means of an electric arc between [[tungsten]] [[electrode]]s housed inside a translucent or transparent [[fused quartz]] or fused [[alumina]] tube. This tube is filled with both [[gas]] and [[metal]] salts. The gas facilitates the arc's initial strike. Once the arc is started, it heats and evaporates the metal salts forming a [[Plasma (physics)|plasma]], which greatly increases the intensity of light produced by the arc and reduces its power consumption. High-intensity discharge lamps are a type of [[arc lamp]].
Compared with [[fluorescent lamp|fluorescent]] and [[incandescent light bulb|incandescent]] lamps, HID lamps have higher [[luminous efficacy]] since a greater proportion of their radiation is in visible light as opposed to heat.
Their [[Luminous_efficacy#Lighting efficiency|overall luminous efficacy]] is also much higher: they give a greater amount of light output per watt of electricity input.
== Construction ==
[[Image:High pressure sodium lamp.svg|thumb|255px|right|Diagram of a high pressure sodium lamp.]]
Various different types of chemistry are used in the arc tubes of HID lamps, depending on the desired characteristics of light intensity, [[Color_temperature#Correlated_color_temperature|correlated color temperature]], [[color rendering index]] (CRI), energy efficiency, and lifespan. Varieties of HID lamp include:
*[[mercury-vapor lamp|Mercury vapor]] lamps
*[[Metal halide lamp|Metal halide]] (MH) lamps
*[[Ceramic discharge metal halide lamp|Ceramic MH]] lamps
*High-pressure and low-pressure [[sodium vapor lamp]]s
*[[Xenon arc lamp|xenon short-arc lamp]]s.
The light-producing element of these lamp types is a well-stabilized [[electric arc|arc]] discharge contained within a refractory envelope ([[arc tube]]) with wall loading in excess of 3 W/cm² (19.4 W/in²).
Mercury vapor lamps were the first commercially available HID lamps. Originally they produced a bluish-green light, but more recent versions can produce light with a less pronounced color tint. However, mercury vapor lamps are falling out of favor and being replaced by sodium vapor and metal halide lamps.
Metal halide and ceramic metal halide lamps can be made to give off neutral white light useful for applications where normal color appearance is critical, such as TV and movie production, indoor or nighttime sports games, automotive headlamps, and aquarium lighting.
Low-pressure sodium vapor lamps are extremely efficient. They produce a deep yellow-orange light and have an effective CRI of nearly zero; items viewed under their light appear monochromatic. This makes them particularly effective as photographic [[safe light]]s. High-pressure sodium lamps tend to produce a much whiter light, but still with a characteristic orange-pink cast. New color-corrected versions producing a whiter light are now available, but some efficiency is sacrificed for the improved color.
==Electronic control gear==
Like fluorescent lamps, HID lamps require a [[ballast (electrical)|ballast]] to start and maintain their arcs. The method used to initially strike the arc varies: mercury vapor lamps and some metal halide lamps are usually started using a third electrode near one of the main electrodes while other lamp styles are usually started using pulses of high voltage.
==Applications==
HID lamps are typically used when high levels of light over large areas are required, and when energy efficiency and/or light intensity are desired. These areas include [[gym]]nasiums, large public areas, [[warehouse]]s, movie theaters, football stadiums<ref>[http://catalogue.ausport.gov.au/fulltext/1998/wa/fo_outdoor_lighting.pdf Focus on Outdoor Lighting, page 4]</ref>, outdoor activity areas, roadways, parking lots, and pathways. More recently, HID lamps, especially metal halide, have been used in small retail and residential environments. HID lamps have made indoor gardening practical, particularly for plants that require a good deal of high intensity sunlight; HID lamps are a common choice of light source for [[marijuana]] growing operations. They are also used to reproduce tropical intensity sunlight for indoor [[aquarium]]s.
Most HID lamps produce significant [[UV radiation]], and require UV-blocking filters to prevent UV-induced degradation of lamp fixture components, fading of dyed items illuminated by the lamp. Exposure to HID lamps operating with faulty or absent UV-blocking filters causes injury to humans and animals, such as [[sunburn]] and [[arc eye]]. Many HID lamps are designed so as to quickly extinguish if their outer UV-shielding glass envelope is broken.
Beginning in the early 1990s, HID lamps have been employed in motor vehicle [[Headlamp#HID light sources (xenon and bi-xenon)|headlamps]]. This application has met with mixed responses from motorists, who appreciate the improved nighttime visibility from HID headlamps but object to the [[Light pollution#Glare|glare]] they can cause. Internationalized [[ECE Regulations|European vehicle regulations]] require such headlamps to be equipped with lens cleaners and an automatic self-leveling system to keep the beams aimed correctly regardless of vehicle load and attitude, but no such devices are required in North America, where inherently more glaring beam patterns are also permitted. Retrofitting HID bulbs in headlamps not originally designed to accept them results in extremely high levels of glare, and is illegal throughout most of the world.<ref>[http://www.danielsternlighting.com/tech/bulbs/Hid/conversions/conversions.html Headlamp HID kits — technical and legal factors]</ref>
HID lamps are used in high-performance [[Bicycle lighting|bicycle headlamps]] as well as [[flashlight]]s and other portable lights, because presently they produce the greatest amount of light per unit of electricity. As the HID lights use less than half the power of an equivalent tungsten-halogen light, a significantly smaller and lighter-weight power supply can be used.
HID lamps are also used on many general aviation aircraft for landing and taxi lights.
== End of life ==
At the end of life, many types of high-intensity discharge lamps exhibit a phenomenon known as ''cycling''. These lamps can be started at a relatively low [[voltage]]. As they heat up during operation, however, the internal gas pressure within the arc tube rises and a higher voltage is required to maintain the [[Electric arc|arc discharge]]. As a lamp gets older, the voltage necessary to maintain the arc eventually rises to exceed the voltage provided by the [[electrical ballast]]. As the lamp heats to this point, the arc fails and the lamp goes out. Eventually, with the arc extinguished, the lamp cools down again, the gas pressure in the arc tube is reduced, and the ballast can once again cause the arc to strike. The effect of this is that the lamp glows for a while and then goes out, repeatedly.
More sophisticated ballast designs detect cycling and give up attempting to start the lamp after a few cycles. If power is removed and reapplied, the ballast will make a new series of startup attempts.
==See also==
*[[Hydrargyrum medium-arc iodide]] lamp
*[[List of light sources]]
*[[Over-illumination]]
== References ==
{{cleanup-references}}
<references/>
*{{cite book
| first = John | last = Waymouth | year = 1971
| title = Electric Discharge Lamps | publisher = The M.I.T. Press
| location = Cambridge, MA | id = ISBN 0-262-23048-8 }}
*{{cite web
| author=National Highway Traffic Safety Administration
| year=
| url=http://www.nhtsa.gov/cars/rules/rulings/glare.html
| title=Glare from headlamps and other front mounted lamps
| work=Federal Motor Vehicle Safety Standard No. 108
| publisher=US Department of Transportation
| accessdate=2006-01-23
| accessyear=
}}
{{ArtificialLightSources}}
{{CarDesign nav}}
[[Category:Gas discharge lamps]]
[[de:Gasentladungslampe#Hochdruckentladungslampe_.28HID-Lampe.29]]
[[ja:HIDランプ]]
[[fi:H.I.D]]
[[zh:高強度氣體放電燈]]