Infrared spectroscopy 15412 222131180 2008-06-27T18:30:19Z DMacks 712163 Reverted edits by [[Special:Contributions/87.84.143.80|87.84.143.80]] ([[User talk:87.84.143.80|talk]]) to last version by JAnDbot {{For|a table of IR spectroscopy data|infrared spectroscopy correlation table}} '''Infrared spectroscopy''' (IR spectroscopy) is the subset of [[spectroscopy]] that deals with the [[infrared]] region of the [[electromagnetic spectrum]]. It covers a range of techniques, the most common being a form of [[absorption spectroscopy]]. As with [[spectroscopy|all spectroscopic techniques]], it can be used to identify compounds or investigate sample composition. [[Infrared spectroscopy correlation table]]s are tabulated in the literature. == Theory == The infrared portion of the electromagnetic spectrum is divided into three regions; the near-, mid- and far- infrared, named for their relation to the visible spectrum. The far-infrared, approximately 400-10&nbsp;[[wavenumber|cm<sup>-1</sup>]] (1000–30&nbsp;μm), lying adjacent to the [[microwave]] region, has low energy and may be used for [[rotational spectroscopy]]. The mid-infrared, approximately 4000-400&nbsp;cm<sup>-1</sup> (30–1.4&nbsp;μm) may be used to study the fundamental vibrations and associated [[Rovibronic excitation|rotational-vibrational]] structure. The higher energy near-IR, approximately 14000-4000&nbsp;cm<sup>-1</sup> (1.4–0.8&nbsp;μm) can excite [[overtones|overtone]] or [[Harmonic (mathematics)|harmonic]] vibrations. The names and classifications of these subregions are merely conventions. They are neither strict divisions nor based on exact molecular or electromagnetic properties. Infrared spectroscopy exploits the fact that molecules have specific frequencies at which they rotate or vibrate corresponding to discrete [[energy level]]s. These [[resonant frequency|resonant frequencies]] are determined by the shape of the molecular [[potential energy surface]]s, the masses of the atoms and, by the associated [[vibronic coupling]]. In order for a vibrational mode in a molecule to be IR active, it must be associated with changes in the permanent dipole. In particular, in the [[Born-Oppenheimer approximation|Born-Oppenheimer]] and harmonic approximations, i.e. when the [[molecular Hamiltonian]] corresponding to the electronic [[ground state]] can be approximated by a [[quantum harmonic oscillator|harmonic oscillator]] in the neighborhood of the equilibrium [[molecular geometry]], the resonant frequencies are determined by the [[normal modes]] corresponding to the molecular electronic ground state potential energy surface. Nevertheless, the resonant frequencies can be in a first approach related to the strength of the bond, and the [[atomic mass|mass of the atoms]] at either end of it. Thus, the frequency of the vibrations can be associated with a particular bond type. Simple diatomic molecules have only one bond, which may stretch. More complex molecules have many bonds, and vibrations can be conjugated, leading to infrared absorptions at characteristic frequencies that may be related to chemical groups. For example, the atoms in a CH<sub>2</sub> group, commonly found in [[organic compound]]s can vibrate in six different ways: '''symmetrical and antisymmetrical stretching''', '''scissoring''', '''rocking''', '''wagging''' and '''twisting''': {| class="wikitable" |- ! Symmetrical<br>stretching ! Antisymmetrical<br>stretching ! Scissoring ! Rocking ! Wagging ! Twisting |- | [[Image:Symmetrical stretching.gif|133px]] | [[Image:Asymmetrical stretching.gif|133px]] | [[Image:Scissoring.gif|133px]] | [[Image:Modo rotacao.gif|133px]] | [[Image:Wagging.gif|133px]] | [[Image:Twisting.gif|133px]] |} The infrared spectrum of a sample is collected by passing a beam of infrared light through the sample. Examination of the transmitted light reveals how much energy was absorbed at each wavelength. This can be done with a [[monochromatic]] beam, which changes in wavelength over time, or by using a [[Fourier transform]] instrument to measure all wavelengths at once. From this, a [[transmittance]] or [[absorbance]] spectrum can be produced, showing at which IR wavelengths the sample absorbs. Analysis of these absorption characteristics reveals details about the molecular structure of the sample. This technique works almost exclusively on samples with [[covalent bond]]s. Simple spectra are obtained from samples with few IR active bonds and high levels of purity. More complex molecular structures lead to more absorption bands and more complex spectra. The technique has been used for the characterization of very complex mixtures. == Sample preparation == <!-- A link on Liquid paraffin targets this paragraph. If you change the sub-heading, please change the link as well. Thanks. --> Gaseous samples require little preparation beyond purification, but a sample cell with a long [[pathlength]] (typically 5-10&nbsp;cm) is normally needed, as gases show relatively weak absorbances. Liquid samples can be sandwiched between two plates of a high purity salt (commonly [[sodium chloride]], or common salt, although a number of other salts such as [[potassium bromide]] or [[calcium fluoride]] are also used). The plates are transparent to the infrared light and will not introduce any lines onto the spectra. Some salt plates are highly soluble in water, so the sample and washing reagents must be [[anhydrous]] (without water). Solid samples can be prepared in four major ways. The first is to crush the sample with a [[mulling agent]] (usually [[nujol]]) in a [[marble]] or [[agate]] mortar, with a pestle. A thin film of the mull is applied onto salt plates and measured. The second method is to grind a quantity of the sample with a specially purified salt (usually [[potassium bromide]]) finely (to remove scattering effects from large crystals). This powder mixture is then crushed in a mechanical [[die press]] to form a translucent pellet through which the beam of the spectrometer can pass. The third technique is the Cast Film technique, which is used mainly for polymeric materials. The sample is first dissolved in a suitable, non hygroscopic solvent. A drop of this solution is deposited on surface of KBr or NaCl cell. The solution is then evaporated to dryness and the film formed on the cell is analysed directly. Care is important to ensure that the film is not too thick otherwise light cannot pass through. This technique is suitable for qualitative analysis. The final method is to use [[microtomy]] to cut a thin (20-100 [[micron]]) film from a solid sample. This is one of the most important ways of analysing failed plastic products for example because the integrity of the solid is preserved. It is important to note that spectra obtained from different sample preparation methods will look slightly different from each other due to differences in the samples' physical states. == Typical method == [[Image:IR spectroscopy apparatus.jpeg|thumbnail|right|400px|Typical apparatus]] A beam of infrared light is produced and split into two separate beams. One is passed through the sample, the other passed through a reference which is often the substance the sample is dissolved in. The beams are both reflected back towards a detector, however first they pass through a splitter which quickly alternates which of the two beams enters the detector. The two signals are then compared and a printout is obtained. A reference is used for two reasons: *This prevents fluctuations in the output of the source affecting the data *This allows the effects of the solvent to be cancelled out (the reference is usually a pure form of the solvent the sample is in) == Summary of absorptions of bonds in organic molecules == {{Main article|Infrared Spectroscopy Correlation Table}} [[Image:IR summary version 2.gif|centre|frame]] Wavenumbers listed in [[wavenumber|cm<sup>-1</sup>]]. == Uses and applications == Infrared spectroscopy is widely used in both research and industry as a simple and reliable technique for measurement, quality control and dynamic measurement. It is of especial use in [[forensic analysis]] in both criminal and civil cases, enabling identification of [[polymer degradation]] for example. It is perhaps the most widely used method of [[applied spectroscopy]].{{Fact|date=May 2008}} The instruments are now small, and can be transported, even for use in field trials. With increasing technology in computer filtering and manipulation of the results, samples in solution can now be measured accurately (water produces a broad absorbance across the range of interest, and thus renders the spectra unreadable without this computer treatment). Some machines will also automatically tell you what substance is being measured from a store of thousands of reference spectra held in storage. By measuring at a specific frequency over time, changes in the character or quantity of a particular bond can be measured. This is especially useful in measuring the degree of polymerization in [[polymer]] manufacture. Modern research machines can take infrared measurements across the whole range of interest as frequently as 32 times a second. This can be done whilst simultaneous measurements are made using other techniques. This makes the observations of chemical reactions and processes quicker and more accurate. Techniques have been developed to assess the quality of tea-leaves using infrared spectroscopy. This will mean that highly trained experts (also called 'noses') can be used more sparingly, at a significant cost saving.<ref>{{citation|last1=Luypaert|first1=J.|last2=Zhang|first2=M.H.|last3=Massart|first3=D.L. |contribution= Feasibility study for the use of near infrared spectroscopy in the qualitative and quantitative analysis of green tea, Camellia sinensis (L.) |title=Analytica Chimica Acta|publisher=Elsevier |year=2003|volume=478(2)|pages=303–312}}</ref> Infrared spectroscopy has been highly successful for applications in both organic and inorganic chemistry. Infrared spectroscopy has also been successfully utilized in the field of semiconductor microelectronics<ref>{{cite book |last= Lau|first= W.S. |coauthors= |title= Infrared characterization for microelectronics |publisher= World Scientific |year= 1999 |month= |isbn= }}</ref>: for example, infrared spectroscopy can be applied to semiconductors like [[silicon]], [[gallium arsenide]], [[gallium nitride]], [[zinc selenide]], amorphous silicon, [[silicon nitride]], etc. ==Isotope effects== The different isotopes in a particular species may give fine detail in infrared spectroscopy. For example, the O-O stretching frequency of oxy[[hemocyanin]] is experimentally determined to be 832 and 788 cm<sup>-1</sup> for ν(<sup>16</sup>O-<sup>16</sup>O) and ν(<sup>18</sup>O-<sup>18</sup>O) respectively. By considering the O-O as a spring, the wavelength of absorbance, ν can be calculated: :<math>\nu = \frac{1}{2 \pi} \sqrt{\frac{k}{\mu}}</math> where ''k'' is the spring constant for the bond, and ''μ'' is the [[reduced mass]] of the A-B system: :<math>\mu = \frac{m_A m_B}{m_A + m_B}</math> (<math>m_i</math> is the mass of atom <math>i</math>). The reduced masses for <sup>16</sup>O-<sup>16</sup>O and <sup>18</sup>O-<sup>18</sup>O can be approximated as 8 and 9 respectively. Thus :<math>\frac{\nu_{^{16}O}}{\nu_{^{18}O}} = \sqrt{\frac{9}{8}} \approx \frac{832}{788}</math> == Fourier transform infrared spectroscopy == {{Main|Fourier transform spectroscopy}} '''Fourier transform infrared (FTIR) spectroscopy''' is a measurement technique for collecting infrared spectra. Instead of recording the amount of energy absorbed when the frequency of the infra-red light is varied (monochromator), the IR light is guided through an [[interferometer]]. After passing the sample the measured signal is the interferogram. Performing a mathematical [[Fourier transform]] on this signal results in a spectrum identical to that from conventional (dispersive) infrared spectroscopy. FTIR spectrometers are cheaper than conventional spectrometers because building of interferometers is easier than the fabrication of a monochromator. In addition, measurement of a single spectrum is faster for the FTIR technique because the information at all frequencies is collected simultaneously. This allows multiple samples to be collected and averaged together resulting in an improvement in sensitivity. Because of its various advantages, virtually all modern infrared spectrometers are FTIR instruments. == Two-dimensional infrared spectroscopy == {{Main|Two-dimensional infrared spectroscopy analysis}} '''Two-dimensional infrared correlation spectroscopy analysis''' is the application of [[2D correlation analysis]] on infrared spectra. By extending the spectral information of a perturbed sample, spectral analysis is simplified and resolution is enhanced. The 2D synchronous and 2D asynchronous spectra represent a graphical overview of the spectral changes due to a perturbation (such as a changing concentration or changing temperature) as well as the relationship between the spectral changes at two different wavenumbers. {{Main|Nonlinear two-dimensional infrared spectroscopy}} [[Image:2DIR pulse sequence.svg|thumbnail|right|400px|Pulse Sequence used to obtain a two-dimensional Fourier transform infrared spectrum. The time period <math>\tau_1</math> is usually referred to as the coherence time and the second time period <math>\tau_2</math> is known as the waiting time. The excitation frequency is obtained by Fourier transforming along the <math>\tau_1</math> axis.]] '''Nonlinear two-dimensional infrared spectroscopy'''<ref>{{cite journal | author = P. Hamm, M. H. Lim, R. M. Hochstrasser | title = Structure of the amide I band of peptides measured by femtosecond nonlinear-infrared spectroscopy | journal = J. Phys. Chem. B | volume = 102 | pages = 6123 | year = 1998 | doi = 10.1021/jp9813286}}</ref><ref>{{cite journal | author = S. Mukamel | title = Multidimensional Fentosecond Correlation Spectroscopies of Electronic and Vibrational Excitations | journal = Annual Review of Physics and Chemistry | volume =51 | pages = 691 | year = 2000 | doi = 10.1146/annurev.physchem.51.1.691 }}</ref> is the infrared version of [[correlation spectroscopy]]. Nonlinear two-dimensional infrared spectroscopy is a technique that has become available with the development of [[femtosecond]] infrared laser pulses. In this experiment first a set of pump pulses are applied to the sample. This is followed by a waiting time, where the system is allowed to relax. The waiting time typically lasts from zero to several picoseconds and the duration can be controlled with a resolution of tens of femtoseconds. A probe pulse is then applied resulting in the emission of a signal from the sample. The nonlinear two-dimensional infrared spectrum is a two-dimensional correlation plot of the frequency <math>\omega_1</math> that was excited by the initial pump pulses and the frequency <math>\omega_3</math> excited by the probe pulse after the waiting time. This allows the observation of coupling between different vibrational modes. Because of its extremely high time resolution it can be used to monitor molecular dynamics on a picosecond timescale. It is still a largely unexplored technique and is becoming increasingly popular for fundamental research. Like in two-dimensional nuclear magnetic resonance (2DNMR) spectroscopy this technique spreads the spectrum in two dimensions and allow for the observation of cross peaks that contain information on the coupling between different modes. In contrast to 2DNMR nonlinear two-dimensional infrared spectroscopy also involve the excitation to overtones. These excitations result in excited state absorption peaks located below the diagonal and cross peaks. In 2DNMR two distinct techniques, [[Correlation spectroscopy#COSY|COSY]] and [[Correlation spectroscopy#NOESY|NOESY]], are frequently used. The cross peaks in the first are related to the scalar coupling, while in the later they are related to the spin transfer between different nuclei. In nonlinear two-dimensional infrared spectroscopy analogs have been drawn to these 2DNMR techniques. Nonlinear two-dimensional infrared spectroscopy with zero waiting time corresponds to COSY and nonlinear two-dimensional infrared spectroscopy with finite waiting time allowing vibrational population transfer corresponds to NOESY. The COSY variant of nonlinear two-dimensional infrared spectroscopy has been used for determination of the secondary structure content proteins.<ref>{{cite journal | author = N. Demirdöven, C. M. Cheatum, H. S. Chung, M. Khalil, J. Knoester, A. Tokmakoff | title= Two-dimensional infrared spectroscopy of antiparallel beta-sheet secondary structure | journal = [[Journal of the American Chemical Society]] | volume = 126 | pages = 7981 | year = 2004 | doi = 10.1021/ja049811j}}</ref> ==See also== {{col-begin}} {{col-3}} *[[Infrared spectroscopy correlation table]] *[[Fourier transform spectroscopy]] *[[Near infrared spectroscopy]] *[[Vibrational spectroscopy]] *[[Rotational spectroscopy]] {{col-3}} *[[Time-resolved spectroscopy]] *[[Spectroscopy]] *[[Quantum vibration]] *[[Raman spectroscopy]] *[[Frequency comb]] *[[Microscopy#Infrared microscopy|Infrared microscopy]] *[[Photothermal microspectroscopy]] {{col-3}} *[[Polymer degradation]] *[[Infrared astronomy]] *[[Far infrared astronomy]] *[[Forensic chemistry]] *[[Forensic engineering]] *[[Forensic polymer engineering]] *[[Forensic science]] *[[Applied spectroscopy]] {{col-end}} ==References== <references/> ==External links== {{commonscat}} * [http://www.scienceofspectroscopy.info The Science of Spectroscopy] - supported by NASA. Spectroscopy education wiki and films - introduction to light, its uses in NASA, space science, astronomy, medicine & health, environmental research, and consumer products. * A useful gif animation of different vibrational modes: [http://www.shu.ac.uk/schools/sci/chem/tutorials/molspec/irspec1.htm here] * [http://www.organicworldwide.net/infrared Infrared spectroscopy for organic chemists] * [http://riodb01.ibase.aist.go.jp/sdbs/cgi-bin/cre_index.cgi?lang=eng Organic compounds spectrum database] {{BranchesofSpectroscopy}} [[Category:Spectroscopy]] [[Category:Scientific techniques]] [[Category:Chemical bonding]] [[Category:Infrared technology]] [[cs:Infračervená spektroskopie]] [[da:IR spektrometer]] [[de:IR-Spektroskopie]] [[el:Φασματοσκοπία υπερύθρου]] [[es:Espectroscopia infrarroja]] [[it:Spettroscopia infrarossa]] [[ms:Spektroskopi inframerah]] [[nl:Infraroodspectroscopie]] [[ja:赤外分光法]] [[no:Infrarød spektroskopi]] [[pl:Spektroskopia IR]] [[pt:Espectroscopia de infravermelho]] [[ru:Инфракрасная спектроскопия]] [[uk:Інфрачервона спектроскопія]]