A '''medical device''' is an object which is useful for diagnostic or therapeutic purposes. Examples of medical devices include [[medical thermometer]]s, [[blood glucose monitoring|blood sugar meter]]s, and [[X-ray machine]]s.
==Definitions==
===European Definition===
DIRECTIVE 2007/47/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 September 2007, which amended the COUNCIL DIRECTIVE 93/42/EEC of 14 June 1993 concerning medical devices, defines a ‘medical device’ as:
any instrument, apparatus, appliance, software, material or other article, whether used alone or in combination, including the software intended by its manufacturer to be used specifically for diagnostic and/or therapeutic purposes and necessary for its proper application, intended by the manufacturer to be used for human beings for the purpose of:
* — diagnosis, prevention, monitoring, treatment or alleviation of disease,
* — diagnosis, monitoring, treatment, alleviation of or compensation for an injury or handicap,
* — investigation, replacement or modification of the anatomy or of a physiological process,
* — control of conception,
and which does not achieve its principal intended action in or on the human body by pharmacological, immunological or metabolic means, but which may be assisted in its function by such means.
The [[Medicines and Healthcare products Regulatory Agency]] (MHRA) regulates medical devices in the UK under European legislation.
Medical devices must not be mistaken with [[medicinal products]].
===Definition in USA by the [[Food and Drug Administration]]===
A '''medical device''' is an [[Tool|instrument]], apparatus, implement, [[machine]], contrivance, [[Implant (medicine)|implant]], [[in vitro]] [[reagent]], or other similar or related article, including a component part, or accessory which is:
* recognized in the official [[National Formulary]], or the [[United States Pharmacopoeia]], or any supplement to them,
* intended for use in the [[diagnosis]] of [[disease]] or other conditions, or in the cure, mitigation, treatment, or [[Prevention (medical)|prevention]] of disease, in man or other animals, or
* intended to affect the structure or any function of the body of man or other animals, and which does not achieve any of its primary intended purposes through chemical action within or on the body of man or other animals and which is not dependent upon being [[metabolism|metabolized]] for the achievement of any of its primary intended purposes.
as defined by the Federal Food, Drug, and Cosmetic Act, 21 [[United States Code]] [321] (h).
===Definition in Canada by the [[Food and Drugs Act]]===
The term Medical Devices, as defined in the Food and Drugs Act, covers a wide range of health or medical instruments used in the treatment, mitigation, diagnosis or prevention of a disease or abnormal physical condition. Health Canada reviews medical devices to assess their safety, effectiveness and quality before being authorized for sale in Canada.
==Classification:==
===''Canada''===
The Medical Devices Bureau of Health Canada has recognized four classes of medical devices based on the level of control necessary to assure the safety and effectiveness of the device.
===''United States''===
The Food and Drug Administration has recognized three classes of medical devices based on the level of control necessary to assure the safety and effectiveness of the device.{{ref|FDA313}} The classification procedures are described in the [[Code of Federal Regulations]], Title 21, part 820 (usually known as '''21 CFR 820''').
====Class I: General Controls====
Class I devices present minimal potential for harm to the user and are often simpler in design than Class II or Class III devices. These devices are subject only to '''general controls'''. General controls cover such issues as manufacturer ''registration'' with the FDA, good ''manufacturing'' techniques, proper ''branding'' and ''labelling'', ''notification'' of the FDA before marketing the device, and general reporting procedures.{{ref|FDA3132}} (Most Class I devices are exempt from the good manufacturing practices and/or the FDA notification regulations.){{ref_label|FDA3132|2|}} These controls are deemed sufficient to provide reasonable assurance of the safety and effectiveness of the device; or the device is not life-supporting or life-sustaining and does not present a reasonable source of [[injury]] through normal usage. Devices in this category include tongue depressors, [[bedpan]]s, elastic [[bandage]]s, examination gloves, and hand-held surgical instruments and other similar types of common equipment. Depending on the "stated/purported use" of a device, it may be necessary to obtain a Premarket Approval (510K) for the device, which is otherwise classifiable as a Class 1 device. Such devices are referred to as "reserved devices". The electrically powered arthroscope (which is really an endoscope powered electrically) is a case in point. While endoscopes are Class 1 devices (usually not needing a PMA), the electrically powered arthroscopes need PMA (510K) although the manual arthroscopes do not.
====Class II: General Controls with Special Controls====
Class II devices are those for which general controls alone are insufficient to assure safety and effectiveness, and additional existing methods are available to provide such assurances. Therefore, Class II devices are also subject to '''special controls''' in addition to the general controls of Class I devices. Special controls may include special labeling requirements, mandatory performance standards, and postmarket surveillance.{{ref_label|FDA3132|2|}} Devices in Class II are held to a higher level of assurance than Class I devices that they will perform as indicated and will not cause injury or harm to patient or user.
Devices in this class are typically [[non-invasive]] and include [[x-ray]] machines, [[Picture archiving and communication system|PACS]], powered [[wheelchair]]s, [[infusion pump]]s, surgical drapes, surgical needles and suture material, and [[acupuncture]] needles.
====Class III: General Controls and Premarket Approval====
A Class III device is one for which insufficient information exists to assure safety and effectiveness solely through the general or special controls sufficient for Class I or Class II devices. Such a device needs '''premarket approval''', a scientific review to ensure the device's safety and effectiveness, in addition to the general controls of Class I. Class III devices are described as those for which "insufficient information exists to determine that general controls are sufficient to provide reasonable assurance of its safety and effectiveness or that application of special controls ... would provide such assurance and if, in addition, the device is life-supporting or life-sustaining, or for a use which is of substantial importance in preventing impairment of human health, or if the device presents a potential unreasonable risk of illness or injury."{{ref|21CFR820.3}}
Examples of Class III devices which require a premarket approval include replacement [[artificial heart valve|heart valve]]s, [[silicone]] gel-filled [[breast implant]]s, implanted cerebral stimulators, implantable [[artificial pacemaker|pacemaker]] pulse generators and endosseous (intra-bone) implants (with the exception of root-form endosseous dental implants which were recently reclassified as Class II).
===''European Union (EU) and European Free Trade Association (EFTA) ===
The classification of medical devices in the European Union is outlined in Annex IX of the Council Directive 93/42/EEC. There are basically four classes, ranging from low risk to high risk.
Class I (including Is & Im)<br />
Class IIa<br />
Class IIb<br />
Class III<br />
The authorisation of medical devices is guaranteed by a [[Declaration of Conformity]]. This declaration is issued by the manufacturer itself, but for products in Class Is, Im, IIa, IIb or III, it should be backed by a [[Certificate of Conformity]] of so-called Notified Body, i.e. an organisation accredited to validate the compliance of the device to the European Directive. Medical devices that pertain to class I (on condition they do not need to be sterilised or are not used to measure a function) can be put on the market purely by self-certification.
The European classification depends on rules that involve the medical device's duration of body contact, its invasive character, its use of an energy source, its effect on the central circulation or nervous system, its diagnostic impact or its incorporation of a medicinal product.
Certified medical devices should have the [[CE mark]] on the packaging, insert leaflets, etc.. These packagings should also show harmonised pictograms and [[EN]] standardised logos to indicate essential features such as instructions for use, expiry date, manufacturer, sterile, don't reuse, etc...
==Notes and References==
#{{note|FDA313}}[http://www.fda.gov/cdrh/devadvice/313.html FDA website: Classify your Medical Device]
#{{note|FDA3132}}[http://www.fda.gov/cdrh/devadvice/3132.html FDA Device Classification]
#{{note|21CFR860.3}}[http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/CFRSearch.cfm?CFRPart=860 Title 21 Food and Drugs Subchapter-H Medical Devices]
* [http://www.fda.gov/cdrh/devadvice/312.html Device Advice - Is the Product a Medical Device]
==List of medical devices==
===High risk devices===
High risk devices are life supports, critical monitoring , energy emitting and other devices whose failure or misuse is reasonably likely to seriously injure patient or staff. Examples includes
*Anesthesia ventilators
*Anesthesia units
*Apnea monitors
*Argon enhanced coagulation units
*Aspirators
*Auto transfusion units
*Invasive Blood pressure units
*Fetal monitors
*Electrosurgical units
*Incubators
*Infusion pump
*Pulse oximeters
*External pacemaker
===Medium risk devices===
These are devices including many diagnostic instruments whose misuse, failure or absence (e.g. out of service with no replacement available would have a significant impact on patient care, but would not be likely to cause direct serious injury. Examples are
*ECG
*EEG
*Treadmills
*Ultrasound sensors
*Phototherapy units
*Endoscopes
*Surgical drill and saws
*Laparoscopic insufflators
*Phonocardiographs
* radiant warmers (Adult)
===Low risk devices===
Devices in this category are those whose failure or misuse is unlikely to result in serious consequences. Some examples for such equipments include
* Electronic thermometer,
* Breast pumps
* Surgical microscope
* Ultrasonic nebulizers
* Sphygmomanometers
* Surgical table
* Surgical lights.
*Temperature monitor
* Aspirators
==See also==
* [[ISO 13485]]
* [[Medical equipment]]
* [[Biomedical engineering]]
* [[Biomedical equipment technician]]
* [[Clinical engineering]]
* [[Durable medical equipment]]
* [[Home medical equipment]]
* [[GHTF]]
== External links ==
* [http://www.ce-marking.com/medical-devices.htm CE-marking.com] Guide on CE marking of Medical Devices (MDs) and In Vitro Diagnostic Medical Devices (IVDs)
* [http://www.iso.org/iso/products/standards/catalogue_ics_browse.htm?ICS1=11&ICS2=040&ICS3=01& 11.040.01: Medical equipment in general] - ISO standard series
* [http://www.fda.gov/cdrh/ US Food and Drug Administration - Center for Devices and Radiological Health]
* [http://www.medicaldevices.org/public/ Medical Devices Manufacturers' Association]
* [http://ec.europa.eu/enterprise/medical_devices/index_en.htm EU Commission Medical Devices Homepage]
* [http://www.mhra.gov.uk/home/idcplg?IdcService=SS_GET_PAGE&nodeId=48 UK Medicines and Healthcare products Regulatory Agency: 'How we regulate medical devices']
* [http://www.ul.com/medical Underwriters Laboratories Medical Business Unit]
* [http://www.q1productions.com/eventPages/event_071029_MedDeviceReimb.php Understanding Coding Requirements & Disseminating CMS Rulings For Medical Devices]
* [http://laws.justice.gc.ca/en/showtdm/cr/SOR-98-282//?showtoc=&instrumentnumber=SOR-98-282 Medical Devices Regulations on Canadian Food and Drugs Act]
* [http://www.hc-sc.gc.ca/dhp-mps/md-im/index_e.html Health Canada Medical Devices Home]
* [http://www.atmedstu.com/Medical%20instruments%20guide/player.html A comprehensive Guide on Medical instruments]
* [http://www.medgadget.com/ Medgadget: Medical device development news]
* [http://www.pqs.nl/ Medical Device consultancy]
* [http://www.tecnologias-sanitarias.com/ Medical device information - in spanish - en español]
* [http://atmedstu.com/surgery/osce%20at%20your%20finger%20tips-i.php Identify these medical instruments]
[[Category:Medical equipment| Medical equipment]]
[[de:Medizinprodukt]]
[[ja:医療機器]]