Medical imaging 234714 225644775 2008-07-14T18:32:01Z Oli Filth 547762 Reverted 1 edit by [[Special:Contributions/78.105.7.161|78.105.7.161]]. ([[WP:TW|TW]]) '''Medical imaging''' refers to the techniques and processes used to create [[image]]s of the human body (or parts thereof) for clinical purposes ([[medical procedure]]s seeking to reveal, [[diagnose]] or examine [[disease]]) or medical science (including the study of normal [[anatomy]] and [[physiology]]). As a discipline and in its widest sense, it is part of [[biological imaging]] and incorporates [[radiology]] (in the wider sense), [[radiological sciences]], [[endoscopy]], (medical) [[thermography]], medical photography and [[microscopy]] (e.g. for human pathological investigations). Measurement and recording techniques which are not primarily designed to produce [[image]]s, such as [[electroencephalography]] ([[EEG]]) and [[magnetoencephalography]] ([[MEG]]) and others, but which produce data susceptible to be represented as [[map]]s (i.e. containing positional information), can be seen as forms of medical imaging. == Overview == In the clinical context, medical imaging is generally equated to [[radiology]] or "clinical imaging" and the medical practitioner responsible for interpreting (and sometimes acquiring) the images is a [[radiologist]]. Diagnostic [[radiography]] designates the technical aspects of medical imaging and in particular the acquisition of medical images. The ''[[radiographer]]'' or ''radiologic technologist'' is usually responsible for acquiring medical images of diagnostic quality, although some radiological interventions are performed by [[radiologist]]s. As a field of scientific investigation, medical imaging constitutes a sub-discipline of [[biomedical engineering]], [[medical physics]] or [[medicine]] depending on the context: Research and development in the area of instrumentation, image acquisition (e.g. [[radiography]]), modelling and quantification are usually the preserve of [[biomedical engineering]], [[medical physics]] and [[computer science]]; Research into the application and interpretation of [[medical image]]s is usually the preserve of [[radiology]] and the medical sub-discipline relevant to medical condition or area of medical science ([[neuroscience]], [[cardiology]], [[psychiatry]], [[psychology]], etc) under investigation. Many of the techniques developed for medical imaging also have [[Science|scientific]] and [[Industry|industrial]] applications. Medical imaging is often perceived to designate the set of techniques that noninvasively produce images of the internal aspect of the body. In this restricted sense, medical imaging can be seen as the solution of [[Mathematics|mathematical]] [[inverse problem]]s. This means that cause (the properties of living tissue) is inferred from effect (the observed signal). In the case of ultrasonography the probe consists of ultrasonic pressure waves and echoes inside the tissue show the internal structure. In the case of projection radiography, the probe is [[X-ray]] [[electromagnetic radiation|radiation]] which is absorbed at different rates in different tissue types such as bone, muscle and fat. == Imaging technology== ===Electron microscopy=== {{Main|Electron microscope}} The electron microscope is a microscope that can magnify very small details with high resolving power due to the use of electrons as the source of illumination, magnifying at levels up to 2,000,000 times. Electron microscopy is employed in [[anatomic pathology]] to identify organelles within the cells. Its usefulness has been greatly reduced by [[immunhistochemistry]] but it is still irreplaceable for the diagnosis of kidney disease, identification of immotile cilia syndrome and many other tasks ===Fluoroscopy=== {{Main|Fluoroscopy}} Fluoroscopy produces real-time images of internal structures of the body in a similar fashion to [[radiography]], but employs a constant input of [[x rays]]. Contrast media, such as barium, iodine, and air are used to visualize internal organs as they work. Fluoroscopy is also used in image-guided procedures when constant feedback during a procedure is required. ===Magnetic resonance imaging (MRI)=== {{Main|Magnetic resonance imaging}} [[Image:Brain Mri nevit.svg|thumb|A brain MRI representation]] A Magnetic Resonance Imaging instrument ([[MRI scanner]]) uses powerful magnets to polarise and excite [[hydrogen]] nuclei (single [[proton]]) in water molecules in human tissue, producing a detectable signal which is spatially encoded resulting in images of the body. In brief, MRI involves the use of three kinds of [[electromagnetic field]]: a very strong (of the order of units of [[tesla (unit)|teslas]]) static magnetic field to polarize the hydrogen nuclei, called the static field; a weaker time-varying (of the order of 1 kHz) for spatial encoding, called the gradient field(s); and a weak [[radio-frequency]] ([[RF]]) field for manipulation of the hydrogen nuclei to produce measurable signals, collected through an [[Antenna (radio)|RF antenna]]. Like CT, MRI traditionally creates a 2D image of a thin "slice" of the body and is therefore considered a [[tomography|tomographic]] imaging technique. Modern MRI instruments are capable of producing images in the form of 3D blocks, which may be considered a generalisation of the single-slice, tomographic, concept. Unlike CT, MRI does not involve the use of [[ionizing radiation]] and is therefore not associated with the same health hazards; for example there are no known long term effects of exposure to strong static fields (this is the subject of some debate; see 'Safety' in [[MRI]]) and therefore there is no limit on the number of scans to which an individual can be subjected, in contrast with [[X-ray]] and [[Computed tomography|CT]]. However, there are well identified health risks associated with tissue heating from exposure to the RF field and the presence of implanted devices in the body, such as pace makers. These risks are strictly controlled as part of the design of the instrument and the scanning protocols used. CT and MRI being sensitive to different properties of the tissue, the appearance of the images obtained with the two techniques differ markedly. In CT, X-rays must be blocked by some form of dense tissue to create an image, therefore the image quality when looking at soft tissues will be poor. While any nucleus with a net nuclear spin can be used, the proton of the hydrogen atom remains the most widely used, especially in the clinical setting, since it is so ubiquitous and returns much signal. This nucleus, present in water molecules, allows excellent soft-tissue contrast. MRI, or "NMR imaging" as it was originally known, has only been in use since the early 1980s. Effects from long term, or repeated exposure, to the intense static magnetic field are not known. ===Nuclear medicine=== {{Main|Nuclear Medicine}} Images from [[gamma camera]]s are used in Nuclear Medicine to detect regions of biological activity that are often associated with diseases. A short lived [[isotope]], such as [[Iodine-123|<sup>123</sup>I]] is administered to the patient. These isotopes are more readily absorbed by biologically active regions of the body, such as tumors or [[fracture]] points in bones. ===Photoacoustic imaging=== {{Main|Photoacoustic imaging in biomedicine}} '''Photoacoustic imaging''' is a recently developed hybrid biomedical imaging modality based on the photoacoustic effect. It combines the advantages of optical absorption contrast with ultrasonic spatial resolution for deep imaging in (optical) diffusive or quasi-diffusive regime. Recent studies have shown that photoacoustic imaging can be used in vivo for tumor angiogenesis monitoring, blood oxygenation mapping, functional brain imaging, and skin melanoma detection etc. ===Positron emission tomography (PET)=== {{Main|Positron Emission Tomography}} Positron emission tomography is primarily used to detect diseases of the brain and heart. Similarly to nuclear medicine, a short-lived isotope, such as <sup>18</sup>F, is incorporated into a substance used by the body such as [[glucose]] which is absorbed by the tumor of interest. PET scans are often viewed alongside [[computed tomography]] scans, which can be performed on the same equipment without moving the patient. This allows the tumors detected by the PET scan to be viewed next to the rest of the patient's anatomy detected by the CT scan. ===Projection radiography=== {{Main|Projectional Radiography}} Radiographs, more commonly known as [[x-rays]], are often used to determine the type and extent of a fracture as well as for detecting pathological changes in the lungs. With the use of [[radio-opaque]] contrast media, such as [[barium]], they can also be used to visualize the structure of the stomach and intestines - this can help diagnose ulcers or certain types of [[colon cancer]]. === Tomography === {{Main|computed tomography}} [[Tomography]] is the method of imaging a single plane, or slice, of an object resulting in a [[tomogram]]. There are several forms of [[tomography]]: * Linear tomography: This is the most basic form of tomography. The X-ray tube moved from point "A" to point "B" above the patient, while the cassette holder (or "bucky") moves simultaneously under the patient from point "B" to point "A." The [[fulcrum]], or pivot point, is set to the area of interest. In this manner, the points above and below the [[focal plane]] are blurred out, just as the background is blurred when panning a camera during exposure. No longer carried out and replaced by [[computed tomography]]. * Poly tomography: This was a complex form of tomography. With this technique, a number of geometrical movements were programmed, such as hypocycloidic, circular, figure 8, and elliptical. Philips Medical Systems [http://www.medical.philips.com/main/index.asp] produced one such device called the 'Polytome.' No longer carried out, replaced by [[computed tomography]]. * Zonography: This is a variant of linear tomography, where a limited arc of movement is used. It is still used in some centres for visualising the kidney during an intravenous urogram (IVU). *Orthopantomography (OPT or OPG): The only common tomographic examination in use. This makes use of a complex movement to allow the radiographic examination of the mandible, as if it were a flat bone. It is often referred to as a "Panaray", but this is incorrect, as it is a trademark of a specific company's equipment *Computed Tomography (CT), or Computed Axial Tomography (CAT): A CT scan, also known as a [[CAT scan]], is a helical tomography (latest generation), which traditionally produces a 2D image of the structures in a thin section of the body. It uses [[X-ray]]s. It has a greater [[ionizing radiation]] dose burden than projection radiography; repeated scans must be limited to avoid health effects. ===Ultrasound=== {{Main|Medical ultrasonography}} [[Medical ultrasonography]] uses high frequency sound waves of between 2.0 to 10.0 [[megahertz]] that are reflected by tissue to varying degrees to produce a 2D image, traditionally on a TV monitor. This is often used to visualize the [[fetus]] in pregnant women. Other important uses include imaging the abdominal organs, heart, male genitalia, and the veins of the leg. While it may provide less anatomical information than techniques such as CT or MRI, it has several advantages which make it ideal as a first line test in numerous situations, in particular that it studies the function of moving structures in real-time. It is also very safe to use, as the patient is not exposed to radiation and the ultrasound does not appear to cause any adverse effects, although information on this is not well documented. It is also relatively cheap and quick to perform. Ultrasound scanners can be taken to critically ill patients in intensive care units, avoiding the danger caused while moving the patient to the radiology department. The real time moving image obtained can be used to guide drainage and biopsy procedures. Doppler capabilities on modern scanners allow the blood flow in arteries and veins to be assessed. == Medical imaging topics == ===Creation of three-dimensional images=== Recently, techniques have been developed to enable CT, MRI and ultrasound scanning software to produce 3D images for the physician. Traditionally CT and MRI scans produced 2D static output on film. To produce 3D images, many scans are made, then combined by computers to produce a 3D model, which can then be manipulated by the physician. 3D ultrasounds are produced using a somewhat similar technique. With the ability to visualize important structures in great detail, 3D visualization methods are a valuable resource for the diagnosis and surgical treatment of many pathologies. It was a key resource for the famous, but ultimately unsuccessful attempt by Singaporean surgeons to separate Iranian twins [[Ladan and Laleh Bijani]] in 2003. The 3D equipment was used previously for similar operations with great success. Other proposed or developed techniques include: * [[Diffuse optical tomography]] * [[Elastography]] * [[Electrical impedance tomography]] * [[Optoacoustic imaging]] * [[Ophthalmology]] ** [[A-scan]] ** [[B-scan]] ** [[Corneal topography]] ** [[Optical coherence tomography]] ** [[Scanning laser ophthalmoscopy]] Some of these techniques are still at a research stage and not yet used in clinical routines. === Non-diagnostic imaging === [[Neuroimaging]] has also been used in experimental circumstances to allow people (especially disabled persons) to control outside devices, acting as a [[brain computer interface]]. ===Medical imaging service=== [[Image:SMPTE RP-133 small.png|thumb|[[SMPTE]] Medical Diagnostic Imaging Test Pattern]] This is a specialized area of [[medical equipment]] service and repair, which is separate from the [[biomedical]] field, although a hospital with their own service group may include them in the biomed department. At one time, there were only two ways to receive training for this field. One was to learn it in the military, and the other was on-the-job training (OJT) from the manufacturer. But since the 1980s several independent training centers have been started. One such school is RSTI [http://www.rsti-training.com/]. There are different means of employment in this occupation. Working for the manufacturer's field service department (OEM), working for a hospital (in-house), and working for an independent (outside, or independent provider). The most stable positions are with the OEM or hospital, as you can remain current through on-going training, and the two have good working relationships. The OEM service engineer can expect to spend a lot of time driving from one site to another during the work day, and working non-standard hours. They will install, remove, diagnose, repair, calibrate, perform preventive maintenance, and interface equipment, all while ensuring good customer relations. You may also be required to do yearly testing of the radiation sources for Federal [http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/CFRSearch.cfm?FR=1020.30] and State compliance. The in-house person is employed by the hospital. With larger medical facilities, travel between the hospitals' other locations may be required to perform the required services. You may also be required to do yearly testing of the radiation sources for compliance. The OEM or independent will provide installation of purchased equipment, and can be used for back-up service. An independent is typically someone who has left an OEM, and started their own service business. Staying up-to-date as an independent can be difficult and expensive, as the OEM is usually reluctant to provide training. However, non-OEM training facilities are available, such as the aforementioned RSTI. Competition for service can be aggressive, with OEM's giving hospitals or clinics a reduction in equipment purchase price if they retain some form of OEM service. The independent may also sell and install refurbished equipment, or de-install equipment. They will repair, calibrate, and perform preventative maintenance. Because many of the tasks associated with imaging service require expensive, specialized equipment, there may be a financial limit to the independent. Typical equipment used routinely are a Storage [[Oscilloscope]] and [[multimeter]] (if servicing old vacuum-state equipment, a VOM would be helpful). Additional equipment: Keithley dosimeter, mAs meter, Biddle contact tachometer, light to radiation template, etc. === Open source software === Several [[open source]] software packages are available for performing analysis of medical images: * [[ImageJ]] * [[Insight Segmentation and Registration Toolkit|ITK]] As well as academic free software: * [[GemIdent]] == See also == * [[Biomedical informatics]] * [[Digital Imaging and Communications in Medicine]] * [[EMMI]] European Master in Molecular Imaging * [[Full-body scan]] * [[Medical examination]] * [[Medical radiography]] * [[Medical test]] * [[Neuroimaging]] * [[Non-invasive (medical)]] * [[PACS (medical imaging)|PACS]] * [[Pneumoencephalogram]] * [[Segmentation (image processing)]] * [[Signal-to-noise ratio]] * [[Tomogram]] ==References == {{reflist}} {{Unreferenced|date=July 2008}} == Further reading == * Wilhelm Burger and Mark J. Burge (2007). [http://www.imagingbook.com/ ''Digital Image Processing: An Algorithmic Approach Using Java'']. Springer. * Tony F. Chan and Jackie Shen (2005). [http://jackieneoshen.googlepages.com/ImagingNewEra.html ''Image Processing and Analysis - Variational, PDE, Wavelet, and Stochastic Methods'']. SIAM * Terry Yoo(Editor) (2004), ''Insight into Images''. ==External links== {{commons|Category:Medical_Imaging}} * [http://rad.usuhs.edu/medpix/index.html Medical Image Database] - MedPix - Free Image Download and CME * [http://crr.medinfo.ufl.edu Curriculum In Radiology Reporting] - Funded by RSNA WWW Education Grant *[http://www.rtstudents.com Medical Imaging Portal] Diagnostic imaging portal with sections on a variety of topics - MRI, NM, US, CT, Radiography, Bone Densitometry and more. *[http://www.imaging-centers.com/ Imaging-Centers.com] is the first searchable directory of medical imaging centers across the United States. * [http://www.radiologyjournal.org Radiology Journal] * [http://www.nucmedinfo.com Nuclear Medicine Information] * [http://www.cirse.org Cardiovascular and Interventional Radiological Society of Europe] * [http://www.medicalimaging.org Medicalimaging.org] - Offers information from peer-reviewed journals on economic and clinical value of medical imaging. * [http://www.medicalimagingnews.com/ Medical Imaging News] - Gathers headlines daily on medical imaging and major modalities. {{Visualization}} [[Category:Image processing]] [[Category:Medical imaging|*]] [[Category:Nuclear medicine]] [[Category:Radiology]] [[Category:Medical physics]] [[ar:تصوير طبي]] [[de:Bildgebendes Verfahren]] [[el:Ακτινοδιαγνωστική]] [[es:Imagen médica]] [[fa:تصویربرداری پزشکی]] [[fr:Imagerie médicale]] [[it:Imaging biomedico]] [[he:דימות רפואי]] [[nl:Beeldvormend onderzoek]] [[ja:医用画像処理]] [[pl:Obrazowanie medyczne]] [[ru:Медицинская визуализация]] [[sv:Medicinsk bildvetenskap]] [[vi:Chẩn đoán hình ảnh]] [[zh:醫學影像]]