Plasma diagnostics
385621
204227238
2008-04-08T15:09:43Z
140.180.20.254
/* Motional Stark effect */
'''Plasma diagnostics''' are experimental techniques used to measure properties of a [[Plasma (physics)|plasma]] such as [[temperature]] and [[density]].
== Langmuir probe ==
Measurements with electric probes, called [[Langmuir probe]]s, are the oldest and most often used procedures for low-temperature plasmas. The method was developed by [[Irving Langmuir]] and his co-workers in the [[1920s]], and has since been further developed in order to extend its applicability to more general conditions than those presumed by Langmuir. Langmuir probe measurements are based on the estimation of [[current (electricity)|current]] versus [[voltage]] characteristics of a [[electrical network|circuit]] consisting of two metallic electrodes that are both immersed in the plasma under study. Two cases are of interest:
(a) The surface areas of the two electrodes differ by several orders of magnitude. This is known as the ''single-probe'' method.
(b) The surface areas are very small in comparison with the dimensions of the vessel containing the plasma and approximately equal to each other. This is the ''double-probe'' method.
Conventional Langmuir probe theory assumes collisionless movement of charge carriers in the space charge sheath around the probe. Further it is assumed that the sheath boundary is well-defined and that beyond this boundary the plasma is completely undisturbed by the presence of the probe. This means that the [[electric field]] caused by the difference between the potential of the probe and the plasma potential at the place where the probe is located is limited to the volume inside the probe sheath boundary.
The general theoretical description of a Langmuir probe measurement requires the simultaneous solution of the [[Poisson equation]], the collision-free [[Boltzmann (Vlasov) equation|Boltzmann equation]], and the [[continuity equation]] with regard to the boundary condition at the probe surface and requiring that, at large distances from the probe, the solution approaches that expected in an undisturbed plasma.
== Magnetic (B-dot) Probe ==
If the magnetic field in the plasma is not stationary, either because the plasma as a whole is transient or because the fields are periodic (radio-frequency heating), the rate of change of the magnetic field with time (<math>\dot B</math>, read "B-dot") can be measured locally with a loop or coil of wire. Such coils exploit [[Faraday's Law]], whereby a changing magnetic field induces an electric field. The induced voltage can be measured and recorded with common instruments.
Also, by [[Ampere's Law]], the magnetic field is proportional to the currents that produce it, so the measured magnetic field gives information about the currents flowing in the plasma. Both currents and magnetic fields are important in understanding fundamental plasma physics.
== Passive spectroscopy ==
Passive spectroscopic methods simply observe the radiation emitted by the plasma.
=== Doppler shift ===
If the plasma (or one ionic component of the plasma) is flowing in the direction of the line of sight to the observer, emission lines will be seen at a different frequency due to the [[Doppler effect]].
=== Doppler broadening ===
The thermal motion of ions will result in a shift of emission lines up or down, depending on whether the ion is moving toward or away from the observer. The magnitude of the shift is proportional to the velocity along the line of sight. The net effect is a characteristic broadening of spectral lines, known as [[Doppler broadening]], from which the ion temperature can be determined.
=== Stark effect ===
The splitting of some emission lines due to the [[Stark effect]] can be used to determine the local electric field.
=== Stark broadening ===
Even if the macroscopic electric field is zero, any single ion will experience an electric field due to the neighboring charged particles in the plasma. This results in a broadening of some lines that can be used to determine the density of the plasma.
=== Motional Stark effect ===
If an atom is moving in a magnetic field, the [[Lorentz force]] will act in opposite directions on the nucleus and the electrons, just as an electric field does. In the frame of reference of the atom, there ''is'' an electric field, even if there is none in the laboratory frame. Consequently, certain lines will be split by the [[Stark effect]]. With an appropriate choice of beam species and velocity and of geometry, this effect can be used to determine the magnetic field in the plasma.
=== Helium Line Ratios ===
The brightness of an [[Atomic spectral line]] emitted by atoms in a gas (or plasma) can be proportional to the gas's temperature, pressure or a weighted sum of both.
Due to the completeness and accuracy of [[collisional radiative model]]s for [[helium]] the temperature and density of plasmas which have helium present can be measured by taking ratios of the emission intensities of various [[Atomic spectral line]]s
== Active spectroscopy ==
Active spectroscopic methods stimulate the plasma atoms in some way and observe the resulting emission of radiation.
=== Laser-induced fluorescence ===
If the plasma is not fully ionized but contains ions that fluoresce, [[laser-induced fluorescence]] can provide very detailed information on temperature, density, and flows.
== Optical effects from free electrons ==
The optical diagnostics above measure line radiation from atoms. Alternatively, the effects of free charges on electromagnetic radiation can be used as a diagnostic.
=== Thomson scattering ===
Scattering of laser light from the electrons in a plasma is known as [[Thomson scattering]]. The electron temperature can be determined very reliably from the [[Doppler broadening]] of the laser line. The electron density can be determined from the intensity of the scattered light, but a careful absolute calibration is required. Although Thomson scattering is dominated by scattering from electrons, since the electrons interact with the ions, in some circumstances information on the ion temperature can also be extracted.
=== Interferometry ===
If a plasma is placed in one arm of an [[Interferometry|interferometer]], the phase shift will be proportional to the plasma density integrated along the path.
=== Faraday rotation ===
The [[Faraday effect]] will rotate the plane of [[polarization]] of a beam passing through a plasma with a magnetic field in the direction of the beam. This effect can be used as a diagnostic of the magnetic field, although the information is mixed with the density profile and is usually an integral value only.
== Neutron diagnostics ==
Fusion plasmas produces 2.5 MeV and 14 MeV neutrons. By measuring the neutron flux, plasma properties such as ion temperature and fusion power can be determined.
[[Category:Plasma physics]]