Switch 28284 225917639 2008-07-16T00:30:03Z GargoyleBot 6678853 Remove per [[Wikipedia:Templates_for_deletion/Log/2008_July_4#Template:Redirectstohere|TfD]]. {{otheruse}} [[Image:switches-electrical.agr.jpg|300px|thumb|Electrical switches. Top, left to right: circuit breaker, [[mercury switch]], wafer switch, [[DIP switch]], surface mount switch, [[reed switch]]. Bottom, left to right: wall switch (U.S. style), miniature toggle switch, in-line switch, push-button switch, rocker switch, microswitch.]] A '''switch''' is a mechanical device used to connect and disconnect a [[circuit]] at will. Switches cover a wide range of types, from subminiature up to industrial plant switching megawatts of power on high voltage distribution lines. In applications where multiple switching options are required (e.g., a [[telephone]] service), mechanical switches have long been replaced by electronic switching devices which can be automated and intelligently controlled. The prototypical model is perhaps a mechanical device (for example a [[railroad switch]]) which can be disconnected from one course and connected to another. The switch is referred to as a "[[logic gate|gate]]" when abstracted to [[mathematics|mathematical]] form. In the philosophy of [[logic]], operational [[argument]]s are represented as [[logic gate]]s. The use of electronic ''gates'' to function as a system of logical gates is the fundamental basis for the [[computer]]&mdash;i.e. a computer is a system of electronic switches which function as logical gates. [[Image:Tactile switches.jpg|thumb|300px|right|Three tactile switches. Major scale is inches.]] ==A simple electrical switch== A simple [[semiconductor]] switch is a [[transistor]]. ===Contacts=== [[Image:On-Off Switch.jpg|100px|thumb|A toggle switch in the "on" position.]] In the simplest case, a switch has two pieces of [[metal]] called ''contacts'' that touch to make a circuit, and separate to break the circuit. The contact material is chosen for its resistance to [[corrosion]], because most metals form [[Electrical insulation|insulating]] [[oxide]]s that would prevent the switch from working. Contact materials are also chosen on the basis of [[electrical conductivity]], [[Hardness (materials science)|hardness]] (resistance to [[Wear#Abrasive wear|abrasive wear]]), [[Strength of materials|mechanical strength]], low cost and low [[toxicity]]<ref>{{cite web |title = General Electric Contact Materials | work = Electrical Contact Catalog (Material Catalog) | publisher = Tanaka Precious Metals | date = 2005 | url = http://www.tanaka-precious.com/catalog/material.html| accessdate = 2007-02-21 }}</ref>. Sometimes the contacts are [[Electroplating|plated]] with [[noble metal]]s. They may be [[design]]ed to wipe against each other to clean off any contamination. Nonmetallic [[electrical conductor|conductor]]s, such as conductive [[plastic]], are sometimes used. ===Actuator=== The moving part that applies the operating force to the contacts is called the ''[[actuator]]'', and may be a '''toggle''' or ''dolly'', a '''rocker''', a '''push-button''' or any type of mechanical linkage ''(see photo).'' ==Contact arrangements== {{anchor|Two-way switch|Three-way switch|Four-way switch}}<!-- this needn't be in section title to operate okay as a redirect to section! (relocating out) --> [[Image:Tpst.jpg|300px|thumb|Triple Pole Single Throw (TPST or 3PST) [[knife switch]] used to short the windings of a 3 phase wind turbine for [[brake|braking]] purposes. Here the switch is shown in the open position.]] A pair of contacts is said to be 'closed' when there is no space between them, allowing [[electricity]] to flow from one to the other. When the contacts are separated by an [[insulator (electric)|insulating air gap]], an air space, they are said to be 'open', and no electricity can flow at typical voltages. Switches can be and are classified according to the arrangement of their contacts in electronics fields&mdash; but [[electrician]]s in the electrical wiring service business and their electrical supplier industries use different nomenclature, such as "one-way", "two-way", "three-way" and "four-way" switches&mdash;which have different meanings in North American and British cultural regions as is delineated in the table below. Some contacts are normally open (Abreviated ''"n.o." or "no"'') until closed by operation of the switch, while others are normally closed (''"n.c. or "nc"'') and opened by the switch action, where the abbreviations given are commonly used on electronics diagrams for clarity of operation in assembly, analysis or troubleshooting. The serve to synchronize meaning with possible mistakes in wiring assembly, where wiring part of switch one way and part another (usually opposite) way will pretty much guarantee things won't work as designed. A switch with both types of contact{{clarifyme|date=July 2008|I think you confused. Off course in a two position switch half is N.O., and half is N.C., but changeover? Citation for the very term, please. Never heard of in a lifetime in electronics.}} is called a [[changeover switch]] or "make-before-break" switch contact, whereas most switches have a spring loaded action which momentarily disconnect the load and so are "break-before-make" types by contrast&mdash; which type is used could be important, if for example, the switch selects two different power sources instead of switching circuit loads, or the circuit load will not and cannot tolerate any interruption in applied power. The terms ''pole'' and ''throw'' are also used to describe switch contact variations. A ''pole'' is a set of contacts, the switch's electrical terminals that are connected to and belong to a single circuit, usually a load. A ''throw'' is one of two or more positions (the nomenclature is also applied to [[rotary switch]]es, which can have many 'throw' positions) that the switch can adopt, which normally, but not always correspond to the number positions the switch handle or rotor can take when connecting between the common lead of the switch and a pole or poles. A throw position which connects no terminals (poles), has a mis-match between positions and positions which connect terminals, but are quite useful to turn things "Off" or for example, alternatively select between two scaled modes of operation. (e.g. Bright illumination, moderate illumination, no illumination.) These terms give rise to abbreviations for the types of switch which are used in the [[electronics]] industry such as "single-pole, single-throw" (SPST) (the simplest type, "on or off") or "single-pole, double-throw" (SPDT), connecting either of two terminals to the common terminal. In [[mains|electrical power]] wiring (i.e. House and building wiring by [[electrician]]s) names generally involving the suffixed word ''"-way"'' are used; however, these terms differ between [[British English|British]] and [[American English|American]] [[English language|English]] and the terms ''two way'' and ''three way'' are used in both with different meanings. {{Anchor|Table of switch comparisons|Table of switch types}} {| class="wikitable" ! Electronics <br/>specification <br/><center>and</center> <br/>abbreviation !valign=top| Expansion <br/>of <br/>abbreviation ! British <br/>mains <br/>wiring <br/>name ! American <br/>electrical<br/>wiring <br/>name ! Description !! Symbol !! [[International Electrotechnical Commission|IEC]] [[IEC 60617|60617]] |------- | '''SPST''' || Single pole, single throw || One way || Two way || A simple on-off switch: The two terminals are either connected together or not connected to anything. An example is a [[light switch]]. || [[Image:SPST-Switch.svg|100px]] || [[Image:Symbol circuit breaker (one-pole).svg]] |------- | '''SPDT''' || Single pole, double throw || Two way || Three way || A simple changeover switch: C (COM, Common) is connected to L1 or to L2. ||rowspan=1| [[Image:SPDT-Switch.svg|100px]] || rowspan=1| [[Image:Symbol change over switch.svg]]<!-- I want cite, a center-off has the same image! There should be another circle indicating center position! User:fabartus, 30 June 2008 ---> |------- | '''SPCO'''<br/>'''SPTT, c.o.''' || Single pole changeover <br /> ''or'' <br /> Single pole, centre off ''or'' <br />Single Pole, Triple Throw|| &nbsp; || &nbsp; || Similar to ''SPDT''. Some suppliers use ''SPCO/SPTT'' for switches with a stable off position in the centre and ''SPDT'' for those without.{{fact|date=July 2008|SPDT is specifically constrained to two positions, and CAN NOT have three, and suppliers catalogs and literature have been inaccurate for my entire career in electronics, or nowadays thirty plus years!|User:fabartus 30 June 2008}} || &nbsp; || &nbsp; |------- | '''DPST''' || Double pole, single throw || Double pole ||Double pole || Equivalent to two ''SPST'' switches controlled by a single mechanism || [[Image:DPST-symbol.svg|100px]] || [[Image:Symbol circuit breaker (two-pole).svg]] |------- | '''DPDT''' || Double pole, double throw || &nbsp; || &nbsp; || Equivalent to two ''SPDT'' switches controlled by a single mechanism: A is connected to B and D to E, or A is connected to C and D to F. ||rowspan=2| [[Image:DPDT-symbol.svg|100px]] || rowspan=2| [[Image:Symbol change over switch (two-pole).svg]] |------- | '''DPCO''' || Double pole changeover <br /> ''or'' Double pole, centre off || &nbsp; || &nbsp; || Equivalent to ''DPDT''. Some suppliers use ''DPCO'' for switches with a stable off position in the centre and ''DPDT'' for those without. |------- | &nbsp; || &nbsp; || Intermediate switch || 4-way switch || ''DPDT'' switch internally wired for polarity-reversal applications: only four rather than six wires are brought outside the switch housing; with the above, B is connected to F and C to E; hence A is connected to B and D to C, or A is connected to C and D to B. || [[Image:crossover-switch-symbol.svg|100px]]<!--should we also show the symbol we use in the multiway switching diagrams further down the page here? [[User:Plugwash|Plugwash]] 8 July 2005 03:08 (UTC)--> || [[Image:Symbol cross switch.svg]] |} Switches with larger numbers of poles or throws can be described by replacing the "S" or "D" with a number or in some cases the letter "T" (for "triple"). In the rest of this article the terms ''SPST'', ''SPDT'' and ''intermediate'' will be used to avoid the ambiguity in the use of the word "way". ===Make-before-break, break-before-make=== In a multi-throw switch, there are two possible transient behaviors as you move from one position to another. In some switch designs, the new contact is made ''before'' the old contact is broken. This is known as '''make-before-break''', and ensures that the moving contact never sees an open circuit (also referred to as a '''shorting switch'''). The alternative is '''break-before-make''', where the old contact is broken ''before'' the new one is made. This ensures that the two fixed contacts are never shorted to each other. Both types of design are in common use, for different applications. ==Biased switches== A biased switch is one containing a [[spring (device)|spring]] that returns the actuator to a certain position. The "on-off" notation can be modified by placing parentheses around all positions other than the resting position. For example, an (on)-off-(on) switch can be switched on by moving the actuator in either direction away from the centre, but returns to the central off position when the actuator is released. The momentary [[push-button]] switch is a type of biased switch. The most common type is a '''push-to-make switch''', which makes contact when the button is pressed and breaks when the button is released. A '''push-to-break switch''', on the other hand, breaks contact when the button is pressed and makes contact when it is released. An example of a push-to-break switch is a button used to release a door held open by an [[electromagnet]]. Changeover push button switches do exist but are even less common. ==Special types== Switches can be designed to respond to any type of mechanical stimulus: for example, vibration (the ''trembler switch''), tilt, air pressure, fluid level (the ''float switch''), the turning of a key (''key switch''), linear or rotary movement (the ''limit switch'' or '''microswitch'''), or presence of a magnetic field (the ''[[reed switch]]''). ===Mercury tilt switch=== The [[mercury switch]] consists of a drop of [[mercury (element)|mercury]] inside a [[glass]] bulb with 2 contacts. The two contacts pass through the glass, and are connected by the mercury when the bulb is tilted to make the mercury roll on to them. This type of switch performs much better than the ball tilt switch, as the liquid metal connection is unaffected by dirt, debris and oxidation, it wets the contacts ensuring a very low resistance bounce free connection, and movement and vibration do not produce a poor contact. ===Knife switch=== [[Knife switch]]es are unique, because rather than emloying an enclosed circuit connection area with a rubber- or plastic-insulated section for the user, the contacts and bridge are fully exposed. The "knife", a flat metal swinging arm, oscillates via user operation between a set of two or more contact areas. The knife and contacts are typically formed of copper, steel, or brass, depending on the application. The primary advantage of a knife switch is the extremely high current capabilities inherent to the design. The amount of surface area on the "knife" that shorts the contacts is also extremely high, allowing a wide range of high voltage or high amperage applications with no circuit degredation, choke, or arcing during the switch throw. Thicker components need only be accompanied by wider contacts to conduct higher voltages, which allows the design to scale extremely well with size. Although knife switches are inferior to traditional switches in applications where user safety are paramount, knife switches are still commonly employed in everyday high-voltage applcations such as building transformers, large power relays, air-conditioning units, etc. ===Others=== Other types of switch include: * [[Centrifugal switch]] * [[DIP switch]] * [[Hall-effect switch]] * [[Inertial switch]] * [[Membrane switch]] * [[Toggle switch]] * [[Transfer switch]] * [[Mindy switch]] * [[Time switch]] * [[Vandal Resistant Switch]] * [[Jamie switch]] ==Intermediate switch== A DPDT switch has six connections, but since polarity reversal is a very common usage of DPDT switches, some variations of the DPDT switch are internally wired specifically for polarity reversal. These crossover switches only have four terminals rather than six. Two of the terminals are inputs and two are outputs. When connected to a battery or other DC source, the 4-way switch selects from either normal or reversed polarity. Intermediate switches are also an important part of multiway switching systems with more than two switches (see next section). ==Multiway switching== <!-- Please do not change this heading name without also updating [[three-way switch]] redirect. Thanx! --> Multiway switching is a method of connecting switches in groups so that any switch can be used to connect or disconnect the load. This is most commonly done with lighting. <!-- its all very well you adding these letters but i don't see any definition of what they mean --> ===Two locations=== [[Image:Twowayswitching.PNG|right|frame|1. First method<br>2. Second method<br>3. Labelling of switch terminals]] Switching a load on or off from two locations (for instance, turning a light on or off from either end of a flight of stairs) requires two SPDT switches. There are two basic methods of wiring to achieve this, and another not recommended. In the first method, mains is fed into the common terminal of one of the switches; the switches are then connected through the L1 and L2 terminals (swapping the L1 and L2 terminals will just make the switches work the other way round), and finally a feed to the light is taken from the common of the second switch. A connects to B or C, D connects to B or C; the light is on if A connects to D, i.e. if A and D both connect to B or both connect to C. The second method is to join the three terminals of one switch to the corresponding terminals on the other switch and take the incoming supply and the wire out to the light to the L1 and L2 terminals. Through one switch A connects to B or C, through the other also to B or C; the light is on if B connects to C, i.e. if A connects to B with one switch and to C with the other. Wiring needed in addition to the mains network (not including protective earths): First method: *double wire between both switches *single wire from one switch to the mains *single wire from the other switch to the load *single wire from the load to the mains Second method: *triple wire between both switches *single wire from any position between the two switches, to the mains *single wire from any position between the two switches, to the load *single wire from the load to the mains If the mains and the load are connected to the system of switches at one of them, then in both methods we need three wires between the two switches. In the first method one of the three wires just has to pass through the switch, which tends to be less convenient than being connected. When multiple wires come to a terminal they can often all be put directly in the terminal. When wires need to be joined without going to a terminal a crimped joint, piece of terminal block, wirenut or similar device must be used and the bulk of this may require use of a deeper backbox. <br clear=all> Using the first method, there are four possible combinations of switch positions: two with the light on and two with the light off. :{| class="wikitable" |- ! Off !! On |- | [[Image:3-way switches position 1.svg]] || [[Image:3-way switches position 2.svg]] |- | [[Image:3-way switches position 3.svg]] || [[Image:3-way switches position 4.svg]] |} ====An unrecommended method==== [[Image:two way switch direct with neutral and hot.png|right|frame|The unrecommended way using the hot and neutral directly]] If there is a hot (a unique phase) and a neutral wire in both switches and just one wire between them where the light is connected (as in the picture), you can then solve the two way switch problem easily: just plug the hot in the top from switch, the neutral in the bottom from switch and the wire that goes to the light in the middle from the switch. This in both switches. Now you have a fully functional two way switch. This works like the first method above: there are four possibilities and just in two of them there is a hot and a neutral connected in the poles of the light. In the other ones, both poles are neutral or hot and then no current flows because the potential difference is zero. The advantage of this method is that it uses just one wire to the light, having a hot and neutral in both switches. The reason why this is not recommended is that the light socket pins may still be hot even with the light off, which poses a risk when changing a bulb. Another problem with this method is that in both switches there will be hot and neutral wires entering a single switch, which can lead to a short circuit in the event of switch failure, unlike the other methods. This method is in defiance of the NEC and the CEC. In nearly any and all applications, neutral conductors should never be switched. Not only is this a shock hazard due to mistakenly believing that a hot conductor is switched off; it is also a fire hazard and can destroy sensitive equipment due to excessive and unbalanced current flowing on hot conductors that would outherwise flow back to ground on the neutral conductor. ===More than two locations=== [[Image:morethantwowayswitching.PNG|100px|right|frame|Three-way switching.<br>1. First method<br>2. Second method<br>3. Labelling of switch terminals]] For more than two locations, the two cores connecting the L1 and L2 of the switches must be passed through an intermediate switch (as explained above) wired to swap them over. Any number of intermediate switches can be inserted, allowing for any number of locations. Wiring needed in addition to the mains network (not including protective earths): First method: *double wire along the sequence of switches *single wire from the first switch to mains *single wire from the last switch to the load *single wire (neutral) from load to mains Second method: *double wire along the sequence of switches *single wire from first switch to last switch *single wire from anywhere between two of the switches to the mains *single wire from anywhere between the same two switches to the load *single wire (neutral) from load to mains Using the first method, there are eight possible combinations of switch positions: four with the light on and four with the light off. :{| class="wikitable" |- ! Off !! On |- | [[Image:4-way switches position 1.svg]] || [[Image:4-way switches position 2.svg]] |- | [[Image:4-way switches position 3.svg]] || [[Image:4-way switches position 4.svg]] |- | [[Image:4-way switches position 5.svg]] || [[Image:4-way switches position 6.svg]] |- | [[Image:4-way switches position 7.svg]] || [[Image:4-way switches position 8.svg]] |} As mentioned above, the above circuit can be extended by using multiple 4-way switches between the 3-way switches to extend switching ability to any number of locations. == Power switching == When a switch is designed to switch significant power, the transitional state of the switch as well as the ability to stand continuous operating currents must be considered. When a switch is on its resistance is near zero and very little power is dropped in the contacts; when a switch is in the off state its resistance is extremely high and even less power is dropped in the contacts. However when the switch is flicked the resistance must pass through a state where briefly a quarter (or worse if the load is not purely resistive) of the load's rated power is dropped in the switch. For this reason, most power switches (most light switches and almost all larger switches) have spring mechanisms in them to make sure the transition between on and off is as short as possible regardless of the speed at which the user moves the rocker. Power switches usually come in two types. A momentary on-off switch (such as on a [[laser pointer]]) usually takes the form of a button and only closes the circuit when the button is depressed. A regular on-off switch (such as on a [[flashlight]]) has a constant on-off feature. Dual-action switches incorporate both of these features. [[Image:dual action switch.GIF|thumb|A diagram of a dual-action switch system]] ==Up or down== Domestic light switches are generally moved up to switch on in the US, but down in most of Europe and Australia. The reason for the difference remains a bit of a mystery. A few hypotheses are often put forward, but none have been validated. Since there is no significant technical reason for either preference, the standards likely developed due to chance and some degree of cultural isolation. == Contact bounce ==<!-- This section is linked from [[Elektronika BK]] --> Contact bounce (also called ''chatter'') is a common problem with mechanical switches and [[relay]]s. Switch and relay contacts are usually made of springy metals that are forced into contact by an actuator. When the contacts strike together, their momentum and elasticity act together to cause bounce. The result is a rapidly pulsed electrical current instead of a clean transition from zero to full current. The waveform is then further modified by the parasitic [[inductance]]s and [[capacitance]]s in the switch and wiring, resulting in a series of damped [[sinusoid]]al [[oscillation]]s. This effect is usually unnoticeable in AC mains circuits, where the bounce happens too quickly to affect most equipment, but causes problems in some [[analogue electronics|analogue]] and [[logic circuit]]s that respond fast enough to misinterpret the on-off pulses as a data stream. [[Sequential logic|Sequential digital logic circuits]] are particularly vulnerable to contact bounce. The voltage waveform produced by switch bounce usually violates the amplitude and timing specifications of the logic circuit. The result is that the circuit may fail, due to problems such as [[Metastability in electronics|metastability]], [[race condition]]s, [[runt pulse]]s and [[glitch]]es. There are a number of techniques for debouncing (mitigating the effects of switch bounce). They can be split into wet contacts, timing based techniques and [[Hysteresis]] based techniques. ===Wet contacts=== Mercury wetted switch contacts do not suffer from bounce, as once the connection is made the mercury keeps the contact conducting during mechanical bounce. Mercury wetted switches are not a popular option today, primarily due to mercury's toxicity. ===Timing based=== Timing based techniques rely on adding sufficient delays that the extra transitions introduced by bounce are ignored. Their big advantage is they do not require any special design on the switch side and so are generally cheaper. However for good performance they must be designed to suit the switch (too much delay and the response will be needlessly sluggish, too little and bounce will not be eliminated). ====Resistor/Capacitor==== [[Image:rc-switch-debouncer.png|right|250px]] If an on/off switch is used with a pull up (or pull down) resistor and a single capacitor is placed over the switch (or across the resistor, but this can cause nasty spikes of current on the power supply lines) then when the switch is closed (generally pressed) the capacitor will almost instantly discharge through the switch. But when the switch is opened (generally released) the capacitor takes some time to recharge. Therefore contact bounce will have negligible effect on the output. The slow edges can be cleaned up with a [[Schmitt trigger]] if necessary. This method has the advantage of fast response to the initial press but the current surges through the switch may be undesirable. Other RC based systems are also possible with various responses and such systems are probably the easiest method when constructing with simple logic gates and discrete components. ====State machines and software==== A [[finite state machine]] or software running on a CPU can be designed to wait a fixed number of clock cycles after any transition before registering another one. This provides a cheap option for debouncing when a [[microprocessor]], [[microcontroller]] or [[gate array]] is already in use but is unlikely to be worthwhile if constructing with single logic gates CLPD's. ===Hysteresis=== Alternatively, it is possible to build in [[hysteresis]] by making the position where a press is detected separate from that where a release is detected. As long as the bounces are small enough not to take the switch between these positions, bounce problems will be eliminated. Hysteresis can be mechanical or electronic (e.g. a [[Schmitt trigger]]). ====Changeover switch==== A changeover switch provides two distinct events, the making of one contact and the breaking of the other. These can be used to feed the inputs of a [[flip-flop (electronics)|flip-flop]]. This way the press will only be detected when the pressed contact is made and the release will only be detected when the released contact is made. When the switch is bouncing around in the middle no change is detected. To get a single logic signal from such a setup a simple [[SR latch]] can be used. ====Variable resistance==== Normal switches are designed to give a hard on-off but it is also possible to design one that varies more gradually between the hard-on and hard-off states. This keeps the output changes caused by bouncing small. Then by feeding the output to a [[Schmitt trigger]] the effect of those bounce based changes can be eliminated. == References == <references/> * Walker, PMB, ''[[Chambers Science and Technology Dictionary]]'', Edinburgh, 1988, ISBN 1852961503 (definition of ''contact bounce'') == See also== *[[Circuit breaker]] *[[Contactor]] *[[Analogue switch]] *[[Underwriters Laboratories|UL]], [[Canadian Standards Association|CSA]], [[VDA]] *[[MOSFET]]s *[[Power symbol]] - the symbols commonly used on an on-off switch *[[Relay]] - A relay is an electrical switch that opens and closes under the control of another electrical circuit == External links == {{Commonscat|Electric switches}} *[http://www.the-home-improvement-web.com/information/how-to/three-way-switch.htm Several Wiring Options] (with diagrams) *[http://www.thecircuitdetective.com/3and4wyinfo.htm Troubleshooting Existing 2/3/4-way Switching] (US/Canada, with diagrams) *[http://www.milwaukeehomeinspectors.com/how-to-install-a-three-way-switch-video How to Install a Three-Way Switch Short Video] (with step by step instructions) *[http://www.ikalogic.com/debouncing.php Tutorial about switch de-bouncing] Analog and digital debouncing are discussed with schematics and example source codes * videos of an arc fault when [http://205.243.100.155/frames/longarc.htm high voltage circuit breakers] fail to interrupt current, creating arcs up to 100ft in use [[Category:Switches]] [[Category:Electrical components]] [[ca:Commutador (elèctric)]] [[da:Omskifter (elektrisk)]] [[de:Schalter (Elektrotechnik)]] [[es:Interruptor eléctrico]] [[fa:سوئیچ]] [[fr:Interrupteur]] [[id:Saklar]] [[it:Interruttore]] [[he:מפסק]] [[nl:Schakelaar]] [[ja:開閉器]] [[ru:Ключ (электротехника)]] [[sk:Spínač]] [[sl:Stikalo]] [[fi:Kytkin (elektroniikka)]] [[sv:Strömbrytare]] [[uk:Роз'єднувач]] [[ur:بدیل]]