Voltammetry
2430192
225491898
2008-07-13T23:52:14Z
OMCV
4052263
/* Types of voltammetry */ added links
[[Image:Linear Potential Sweep.JPG|right|400px|thumb|'''Linear potential sweep''']]
[[Image:Linear Potential Sweep Anodic Stripping Voltammetry.JPG|right|400px|thumb|'''Potential as a function of time for [[anodic stripping voltammetry]]''']]
'''Voltammetry''' is a category of [[electroanalytical methods]] used in [[analytical chemistry]] and various industrial processes. In voltammetry, information about an analyte is obtained by measuring the current as the potential is varied.
== Three electrode system ==
'''Voltammetry''' experiments investigate the half cell reactivity of an [[analyte]]. Most experiments control the [[potential]] ([[volt]]s) of an electrode in contact with the anaylte while measuring the resulting [[current]] ([[amp]]s).<ref>Bard, A.J.; Faulkner, L.R. '''Electrochemical Methods: Fundamentals and Applications.''' New York: John Wiley & Sons, 2nd Edition, '''2000'''.</ref>
To conduct such an experiment requires at least two electrodes. The [[working electrode]], which makes contact with the analyte, must apply the desired potential in a controlled way and facilitate the transfer of [[electron]]s to and from the analyte. A second electrode acts as the other half of the cell. This second electrode must have a known potential with which to gauge the potential of the working electrode, furthermore it must balance the electrons added or removed by the working electrode. While this is a viable setup, it has a number of shortcomings. Most significantly, it is extremely difficult for an electrode to maintain a constant potential while passing current to counter redox events at the working electrode.
To solve this problem, the role of supplying electrons and referencing potential has been divided between two separate electrodes. The [[reference electrode]] is a half cell with a known reduction potential. Its only role is to act as reference in measuring and controlling the working electrodes potential and at no point does it pass any current. The [[auxiliary electrode]] passes all the current needed to balance the current observed at the working electrode. To achieve this current, the auxiliary will often swing to extreme potentials at the edges of the solvent window, where it oxidizes or reduces the solvent or supporting electrolyte. These electrodes, the [[working electrode|working]], [[reference electrode|reference]], and [[auxiliary electrode|auxiliary]] make up the modern three electrode system.
There are many systems which have more electrodes, but their design principles are generally the same as the three electrode system. For example, the [[rotating ring-disk electrode]] has two distinct and separate working electrodes, a disk and a ring, which can be used to scan or hold potentials independently of each other. Both of these electrodes are balanced by a single reference and auxiliary combination for an over all four electrode design. More complicated experiments may add working electrodes as required and at times reference or auxiliary electrodes.
In practice it can be very important to have a working electrode with known dimensions and surface characteristics. As a result, it is common to clean and polish working electrodes regularly. The auxiliary electrode can be almost anything as long as it doesn't react with the bulk of the anaylte solution and conducts well. The reference is the most complex of the three electrodes, there are a variety of standards used and its worth investigating elseware. For non-aqueous work, [[IUPAC]] recommends the use of the [[ferrocene]]/[[ferrocenium]] couple as an internal standard. In most voltammetry experiments a [[electrolyte|bulk electrolyte]] (also known as supporting electrolyte) is used to minimize solution resistance. It can be possible to run an experiment without an bulk electrolyte but the added resistance greatly reduces accuracy of the results. In the case of [[room temperature ionic liquid]]s the solvent can act as the electrolyte.
== Theory ==
The [[Nernst equation]] is fundamental to voltammetry and can be used for a reversible reaction. In this equation the R represents the reduced species and O the oxidized.
<math>E = E^0 - \cfrac{RT}{nF} ln\cfrac{c_R^0}{c_O^0}</math>
R = Molar gas constant<br />
T = temperature in K<br />
n = number of electrons transferred (as determined by the stoichiometry of the cell reaction)<br />
F = Faraday constant<br />
E = applied potential<br />
E<sup>0</sup> = standard reduction potential
<br />
Another useful equation in voltammetry is the [[Butler-Volmer equation]]. This equation represents the relationship between concentration, current, and potential.
<math>\cfrac{i}{nFA} = k^0\lbrace c_O^0 exp[-\alpha\theta]-c_R^0 exp[(1-\alpha)\theta]\rbrace</math>
<math>\theta = nF(E-E^0)/RT</math><br />
<math>k^0</math> = heterogeneous rate constant<br />
<math>\alpha</math> = transfer coefficient<br />
A = area of the electrode<br />
i = current<br />
n = number of electrons transferred
== Types of voltammetry ==
* '''[[Linear sweep voltammetry]]'''
* '''[[Staircase voltammetry]]'''
* '''[[Squarewave voltammetry]]'''
* '''[[Cyclic voltammetry]]''' - A voltammetric method that can be used to determine diffusion coefficients and half cell [[reduction potential]]s.
* '''[[Anodic stripping voltammetry]]''' - A quantitative, analytical method for trace analysis.
* '''[[Cathodic stripping voltammetry]]''' - A quantitative, analytical method for trace analysis.
* '''[[Adsorptive stripping voltammetry]]''' - A quantitative, analytical method for trace analysis.
* '''[[Alternating current voltammetry]]'''
* '''[[Polarography]]''' - a subclass of voltammetry where the working electrode is a [[dropping mercury electrode]] (DME), useful for its wide cathodic range and renewable surface.
* '''[[Rotated electrode voltammetry]]''' - A [[hydrodynamic technique]] in which the working [[electrode]], usually a [[rotating disk electrode]] (RDE) or [[rotating ring-disk electrode]] (RRDE), is rotated at a very high rate. This technique is useful for studying the [[kinetics]] and [[electrochemical reaction mechanism]] for a [[half reaction]].
* '''[[Normal pulse voltammetry]]'''
* '''[[Differential pulse voltammetry]]'''
* '''[[Chronoamperometry]]'''
== History ==
The beginning of voltammetry was facilitated by the discovery of [[polarography]] in 1922 by the Nobel Prize winning chemist [[Jaroslav Heyrovský]]. Early voltammetric techniques had many problems, limiting their viability for everyday use in analytical chemistry. The 1960s and 1970s saw many advances in the theory and instrumentation of all voltammetric methods. These advancements improved sensitivity and created new analytical methods. Industry responded with the production of cheaper instruments that could be effectively used in routine analytical work.
== Applications ==
'''Voltametric Sensors'''
A number of voltammetric systems are produced commercially for the determination of specific species that are of interest in industry and research. These devices are sometimes called [[electrodes]] but are, in fact, complete voltammetric cells and are better referred to as [[sensors]].
'''The Oxygen Electrode'''
The determination of dissolved oxygen in a variety of aqueous environments, such as sea water, blood, sewage, effluents from chemical plants, and soils is of tremendous importance to industry, biomedical and environmental research, and clinical medicine. One of the most common and convenient methods for making such measurements is with the [[Clark oxygen sensor]], which was patented by L.C. Clark Jr., in 1956.
==See also==
[[Electroanalytical Methods]]
==References==
{{reflist}}
1. http://www.drhuang.com/science/chemistry/electrochemistry/polar.doc.htm
2. http://www.autolab-instruments.com/download/content/Appl021.pdf
3. http://www.amelchem.com/download/items/voltammetry/manuals/eng/manual_eng.pdf
4. http://new.ametek.com/content-manager/files/PAR/App%20Note%20E-4%20-%20Electrochemical%20Analysis%20Techniques1.pdf
5. http://www.prenhall.com/settle/chapters/ch37.pdf
{{Analytical chemistry}}
[[Category:Analytical chemistry]]
[[Category:Scientific techniques]]
[[ca:Voltamperometria]]
[[cs:Polarografie]]
[[de:Voltammetrie]]
[[fr:Voltammétrie]]
[[it:Voltammetria]]
[[nl:voltammetrie]]
[[ja:ボルタンメトリー]]
[[pl:Woltamperometria]]
[[ru:Полярография]]